ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors.

https://repo.qst.go.jp/records/85430
https://repo.qst.go.jp/records/85430
e7cf6cf2-5da7-430d-b7a4-3f6d1f6edc5a
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-12-23
タイトル
タイトル MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Okada, Satoshi

× Okada, Satoshi

WEKO 1029445

Okada, Satoshi

Search repository
Takayasu, Satoko

× Takayasu, Satoko

WEKO 1029446

Takayasu, Satoko

Search repository
Sumiyoshi, Akira

× Sumiyoshi, Akira

WEKO 1029447

Sumiyoshi, Akira

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 1029448

Aoki, Ichio

Search repository
Nakamura, Hiroyuki

× Nakamura, Hiroyuki

WEKO 1029449

Nakamura, Hiroyuki

Search repository
Akira, Sumiyoshi

× Akira, Sumiyoshi

WEKO 1029450

en Akira, Sumiyoshi

Search repository
Ichio, Aoki

× Ichio, Aoki

WEKO 1029451

en Ichio, Aoki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Glucose sensors for NMR relaxometry and magnetic resonance imaging (MRI) can be used for the direct measurement of glucose in turbid biological specimens. Here, we proposed a magnetic glucose sensor based on superparamagnetic iron oxide (SPIO) nanoparticles conjugated to a mannopyranoside derivative and concanavalin A (ConA). The binding of mannopyranoside groups to ConA produced a nanoparticle cluster that was dissociated by competitive binding of glucose to ConA, resulting in changes in the transverse relaxation time (T) in a glucose-dependent manner. The sensor gave rise to significant T changes in physiological glucose levels of 3 - 8 mM at a nanoparticle concentration of 0.5 nM. Significant T responses were observed within 6 min of 5 mM glucose detection. Sensor-based MRI by a benchtop 1 tesla scanner permitted a measurement of multiple samples within 8 min. These results demonstrate that the relaxometric glucose sensor could lead to high throughput direct assay of blood samples by using a compact MRI scanner for point-of-care testing.
書誌情報 Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

巻 37, 号 12, p. 1765-1769-1769, 発行日 2021-12
出版者
出版者 Japan Society For Analytical Chemistry
ISSN
収録物識別子タイプ ISSN
収録物識別子 0910-6340
PubMed番号
識別子タイプ PMID
関連識別子 34248090
DOI
識別子タイプ DOI
関連識別子 10.2116/analsci.21P082
関連サイト
識別子タイプ URI
関連識別子 https://www.jstage.jst.go.jp/article/analsci/37/12/37_21P082/_article/-char/ja/
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:01:18.422706
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3