5th edition of the international intercomparison of integrating radon & thoron monitors with the NIRS radon and thoron chambers

https://repo.qst.go.jp/records/71490
https://repo.qst.go.jp/records/71490
4fe246ba-1725-4e8f-b2aa-dfe8f03f5960
Item type 会議発表用資料 / Presentation(1)
公開日 2014-09-16
タイトル
タイトル 5th edition of the international intercomparison of integrating radon & thoron monitors with the NIRS radon and thoron chambers
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 ミロソラフ, ヤニック

× ミロソラフ, ヤニック

WEKO 702972

ミロソラフ, ヤニック

Search repository
Yonehara, Hidenori

× Yonehara, Hidenori

WEKO 702973

Yonehara, Hidenori

Search repository
ミロソラフ ヤニック

× ミロソラフ ヤニック

WEKO 702974

en ミロソラフ ヤニック

Search repository
米原 英典

× 米原 英典

WEKO 702975

en 米原 英典

Search repository
抄録
内容記述タイプ Abstract
内容記述 The 5th international intercomparison for integrating radon detectors was conducted at NIRS (National Institute of Radiological Science, Japan) with a 24.4 m3 inner volume walk-in radon chamber that has systems to control radon concentration, temperature and humidity.
Also, the 4th thoron intercomparison was provided at NIRS thoron chamber with a 150 dm3 inner volume.
Twenty seven laboratories from 19 countries participated in the radon intercomparison, using three types of detectors (etched-track, electret plate, and silicon photodiode). Thirteen laboratories from eleven countries participated in the thoron intercomparisons, using two types of detectors (CR-39 and silicon photodiode).
The tests were made under two different expositions of radon and two of thoron. Finally, 72% and 42% results do not differ more than 20% from the reference value of radon and thoron experiments, respectively.
The presented data indicated that the performance quality of laboratories for radon measurement not changed from previous exercises.
Results of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 8th International Conference on High Levels of Natural Radiation and Radon Areas (ICHLNRRA 2014)
発表年月日
日付 2014-09-04
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:50:39.973915
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3