{"created":"2023-05-15T14:52:21.674149+00:00","id":71490,"links":{},"metadata":{"_buckets":{"deposit":"4089793c-d2fa-4af3-b5da-c2b1ab4696d1"},"_deposit":{"created_by":1,"id":"71490","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"71490"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00071490","sets":["10:28"]},"author_link":["702974","702975","702973","702972"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2014-09-04","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The 5th international intercomparison for integrating radon detectors was conducted at NIRS (National Institute of Radiological Science, Japan) with a 24.4 m3 inner volume walk-in radon chamber that has systems to control radon concentration, temperature and humidity.\nAlso, the 4th thoron intercomparison was provided at NIRS thoron chamber with a 150 dm3 inner volume.\nTwenty seven laboratories from 19 countries participated in the radon intercomparison, using three types of detectors (etched-track, electret plate, and silicon photodiode). Thirteen laboratories from eleven countries participated in the thoron intercomparisons, using two types of detectors (CR-39 and silicon photodiode). \nThe tests were made under two different expositions of radon and two of thoron. Finally, 72% and 42% results do not differ more than 20% from the reference value of radon and thoron experiments, respectively.\nThe presented data indicated that the performance quality of laboratories for radon measurement not changed from previous exercises.\nResults of thoron exercises showed that the quality for thoron measurements still needs further development and additional studies are needed to improve its measuring methods.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"8th International Conference on High Levels of Natural Radiation and Radon Areas (ICHLNRRA 2014)","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"ミロソラフ, ヤニック"}],"nameIdentifiers":[{"nameIdentifier":"702972","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yonehara, Hidenori"}],"nameIdentifiers":[{"nameIdentifier":"702973","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"ミロソラフ ヤニック","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702974","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"米原 英典","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"702975","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"5th edition of the international intercomparison of integrating radon & thoron monitors with the NIRS radon and thoron chambers","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"5th edition of the international intercomparison of integrating radon & thoron monitors with the NIRS radon and thoron chambers"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2014-09-16"},"publish_date":"2014-09-16","publish_status":"0","recid":"71490","relation_version_is_last":true,"title":["5th edition of the international intercomparison of integrating radon & thoron monitors with the NIRS radon and thoron chambers"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:50:39.876763+00:00"}