ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

INDUCTION OF DNA DSB AND ITS REJOINING IN THE CLAMPED AND NON-CLAMPED TUMORS AFTER CARBON ION BEAMS COMPARED WITH X RAYS

https://repo.qst.go.jp/records/69928
https://repo.qst.go.jp/records/69928
3c1b1074-b40c-4b4c-9276-071dd6de7d5d
Item type 会議発表用資料 / Presentation(1)
公開日 2009-11-09
タイトル
タイトル INDUCTION OF DNA DSB AND ITS REJOINING IN THE CLAMPED AND NON-CLAMPED TUMORS AFTER CARBON ION BEAMS COMPARED WITH X RAYS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hirayama, Ryoichi

× Hirayama, Ryoichi

WEKO 686618

Hirayama, Ryoichi

Search repository
Uzawa, Akiko

× Uzawa, Akiko

WEKO 686619

Uzawa, Akiko

Search repository
Matsumoto, Yoshitaka

× Matsumoto, Yoshitaka

WEKO 686620

Matsumoto, Yoshitaka

Search repository
Noguchi, Miho

× Noguchi, Miho

WEKO 686621

Noguchi, Miho

Search repository
Kase, Yuuki

× Kase, Yuuki

WEKO 686622

Kase, Yuuki

Search repository
Ito, Atsushi

× Ito, Atsushi

WEKO 686623

Ito, Atsushi

Search repository
Okayasu, Ryuichi

× Okayasu, Ryuichi

WEKO 686624

Okayasu, Ryuichi

Search repository
Koike, Sachiko

× Koike, Sachiko

WEKO 686625

Koike, Sachiko

Search repository
Ando, Koichi

× Ando, Koichi

WEKO 686626

Ando, Koichi

Search repository
Furusawa, Yoshiya

× Furusawa, Yoshiya

WEKO 686627

Furusawa, Yoshiya

Search repository
平山 亮一

× 平山 亮一

WEKO 686628

en 平山 亮一

Search repository
鵜澤 玲子

× 鵜澤 玲子

WEKO 686629

en 鵜澤 玲子

Search repository
松本 孔貴

× 松本 孔貴

WEKO 686630

en 松本 孔貴

Search repository
加瀬 優紀

× 加瀬 優紀

WEKO 686631

en 加瀬 優紀

Search repository
伊藤 敦

× 伊藤 敦

WEKO 686632

en 伊藤 敦

Search repository
岡安 隆一

× 岡安 隆一

WEKO 686633

en 岡安 隆一

Search repository
小池 幸子

× 小池 幸子

WEKO 686634

en 小池 幸子

Search repository
古澤 佳也

× 古澤 佳也

WEKO 686635

en 古澤 佳也

Search repository
抄録
内容記述タイプ Abstract
内容記述 We studied DSB induction and rejoining in the clamped and non-clamped tumors after low- and high-LET radiations. SCCVII cells were transplanted into the right hind legs of C3H male mice. Conditioning irradiation with either 80 keV/μm carbon ions or 200 kVp X rays was delivered to the tumors at 5 mm diameter. Hypoxic cells were produced by clamping tumor-bearing mice 15min before irradiation in situ. Immediately after and 1 hr after irradiation, tumors were excised and rapidly cooled on ice. DSB in the tumors was analyzed by a static-field gel electrophoresis, and assayed for DSB induction and rejoining. The DSB immediately after X rays under normoxic condition was higher than under hypoxic condition. These damages in both tumor conditions were rejoined 60 to 70% within 1 hr in situ. The OER of DSB after X rays was 1.68 ± 0.31, and this value was not changed by 1 hr rejoining incubation (1.40 ± 0.26). On the other hand, no difference between X rays and carbon ions was found for the induction and rejoining of DSB. The rejoined fraction and the OER of DSB after carbon ions were similar to that after X rays. Additionally, the RBE of DSB immediately after and 1 hr after irradiation, these values were 0.9 to 1.3, and were not dependent on gases conditions. The yields of DSB induced by X rays in vivo might be similar to that after carbon ions, because the OER and RBE were not found a major difference.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 MICROS 2009 15th International Symposium on Microdosimetry
発表年月日
日付 2009-10-30
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 20:08:48.939376
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3