ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. 口頭発表

Introduction of Micro-beam System in NIRS

https://repo.qst.go.jp/records/60123
https://repo.qst.go.jp/records/60123
3d1f0f35-c8f3-49b8-91c0-82533731513d
Item type 会議発表用資料 / Presentation(1)
公開日 2003-11-12
タイトル
タイトル Introduction of Micro-beam System in NIRS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Imaseki, Hitoshi

× Imaseki, Hitoshi

WEKO 597797

Imaseki, Hitoshi

Search repository
Ishikawa, Takahiro

× Ishikawa, Takahiro

WEKO 597798

Ishikawa, Takahiro

Search repository
Iso, Hiroyuki

× Iso, Hiroyuki

WEKO 597799

Iso, Hiroyuki

Search repository
Hamano, Tsuyoshi

× Hamano, Tsuyoshi

WEKO 597800

Hamano, Tsuyoshi

Search repository
Matsumoto, Kenichi

× Matsumoto, Kenichi

WEKO 597801

Matsumoto, Kenichi

Search repository
Yasuda, Nakahiro

× Yasuda, Nakahiro

WEKO 597802

Yasuda, Nakahiro

Search repository
Yukawa, Masae

× Yukawa, Masae

WEKO 597803

Yukawa, Masae

Search repository
今関 等

× 今関 等

WEKO 597804

en 今関 等

Search repository
石川 剛弘

× 石川 剛弘

WEKO 597805

en 石川 剛弘

Search repository
濱野 毅

× 濱野 毅

WEKO 597806

en 濱野 毅

Search repository
松本 健一

× 松本 健一

WEKO 597807

en 松本 健一

Search repository
安田 仲宏

× 安田 仲宏

WEKO 597808

en 安田 仲宏

Search repository
湯川 雅枝

× 湯川 雅枝

WEKO 597809

en 湯川 雅枝

Search repository
抄録
内容記述タイプ Abstract
内容記述 National Institute of Radiological Sciences (NIRS) was established in 1957 as a special research institute for research and medical application of radiation, attached to the Science and Technology Agency of Japan. In 1961, NIRS started to use a Van de Graff accelerator (Model KN3000, High Voltage Engineering) for PIXE (Particle Induced X-ray Emission) analysis that was operated as a device for pre-tumor therapy with neutron and finally discarded in 1997. In March 1999, an electrostatic accelerator, HVEE Tandetron, was installed in the Electrostatic Accelerator Building for PIXE analysis. PIXE analysis is a trace analytical method, which has the advantage of simultaneous determination of elemental concentrations in a small specimen without any chemical separation by measuring characteristic X-rays of elements induced by accelerated charged nuclear particles such as protons. [1]
In this paper, characteristics of the PIXE system and the new microbeam irradiation facility, Single Particle Irradiation System to Cell (SPICE), which is introduced to our Tandem accelerator are described.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 3rd International Symposium on Future Medical Engineering based on BIO-nanotechnology
発表年月日
日付 2003-11-06
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 21:57:15.145669
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3