WEKO3
アイテム
Validating α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors
https://repo.qst.go.jp/records/48626
https://repo.qst.go.jp/records/4862692a0e2b2-e23a-4932-92c3-c32509d06d46
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2017-06-30 | |||||
タイトル | ||||||
タイトル | Validating α-particle emission from 211At-labeled antibodies in single cells for cancer radioimmunotherapy using CR-39 plastic nuclear track detectors | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Kodaira, Satoshi
× Kodaira, Satoshi× Li, Huizi× Konishi, Teruaki× KItamura, Hisashi× Kurano, Mieko× Hasegawa, Sumitaka× Kodaira, Satoshi× Li, Huizi× Konishi, Teruaki× Kitamura, Hisashi× Kurano, Mieko× Hasegawa, Sumitaka |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Recently, 211At has received increasing attention as a potential radionuclide for cancer radioimmunotherapy. It is a α-particle emitter, which is extremely effective against malignant cells. We demonstrate a method to verify the efficiency of 211At-labeled trastuzumab antibodies (211At-trastuzumab) against HER2 antigens, which has not been determined for radioimmunotherapy. A CR-39 plastic nuclear detector is used for measuring the position and the linear energy transfer (LET) of individual 211At α- particle tracks. The tracks and 211At-trastuzumab-binding cells were co-visualized by using the geometric information recorded on the CR-39. HER2-positive human gastric cancer cells (NCI-N87), labelled with 211At-trastuzumab, were dropped on the centre of the CR-39 plate. Microscope images of the cells and the corresponding α-tracks acquired by position matching were obtained. In addition, 3.5 cm × 3.5 cm macroscopic images of the whole plate were acquired. The distribution of number of α-particles emitted from single cells suggests that 80% of the 211At-trastuzumab-binding cells emitted α-particles. It also indicates that the α-particles may strike the cells several times along their path. The track-averaged LET of the α-particles is evaluated to be 131 keV/μm. These results will enable quantitative evaluation of delivered doses to target cells, and will be useful for the in vitro assessment of 211At-based radioimmunotherapeutic agents. | |||||
書誌情報 |
PLOS ONE 巻 12, 号 6, p. e0178472-1-e0178472-13, 発行日 2017-06 |
|||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1371/journal.pone.0178472 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0178472 |