Visualization of free radical reactions in an aqueous sample irradiated by 290 MeV carbon beam

https://repo.qst.go.jp/records/48487
https://repo.qst.go.jp/records/48487
155a7072-dccf-4e28-9de8-6e057346f395
Item type 学術雑誌論文 / Journal Article(1)
公開日 2009-04-27
タイトル
タイトル Visualization of free radical reactions in an aqueous sample irradiated by 290 MeV carbon beam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ken-ichiro, Matsumoto

× Ken-ichiro, Matsumoto

WEKO 1014261

Ken-ichiro, Matsumoto

Search repository
Nagata, Katsura

× Nagata, Katsura

WEKO 1014262

Nagata, Katsura

Search repository
Yamamoto, Haruhiko

× Yamamoto, Haruhiko

WEKO 1014263

Yamamoto, Haruhiko

Search repository
Endo, Kazutoyo

× Endo, Kazutoyo

WEKO 1014264

Endo, Kazutoyo

Search repository
Anzai, Kazunori

× Anzai, Kazunori

WEKO 1014265

Anzai, Kazunori

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 1014266

Aoki, Ichio

Search repository
Kenichiro, Matsumoto

× Kenichiro, Matsumoto

WEKO 1014267

en Kenichiro, Matsumoto

Search repository
Kazunori, Anzai

× Kazunori, Anzai

WEKO 1014268

en Kazunori, Anzai

Search repository
Ichio, Aoki

× Ichio, Aoki

WEKO 1014269

en Ichio, Aoki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The detection of free radical reactions in a gelatin sample irradiated by heavy-ion beam was tested using electron paramagnetic resonance (EPR) spectroscopic and MRI methods. Geometry and the amount of free radical eneration in a sample are described. A reaction mixture containing glutathione and a nitroxyl radical, TEMPOL, was caked with gelatin, and then irradiated with a 290 MeV carbon beam. The amount of free radical generation in a solic sample was almost flat from the surface to the beam end, except for a small peak, the peak radioactivation profile, and then steeply decrased approaching the beam end. Total free radical reactions obtained with carbon-beam irradication were expected to be less than one-third of X-ray irradiation, when the same dose for a deeper target was considered. Both EPR and MRI are useful tools to visualize free radical generation in samples irradiated by a heavy-ion beam. The EPR-based method is more sensitive and quantitative than the MRI-based method; however, the MRI method can achieve high spatial resolution. This study gives the rationale for a redox regulation trial using antioxidant drugs to reduce the side effects on normal tissues in carbon-beam therapy.
書誌情報 Magnetic Resonance in Medicine

巻 61, 号 5, p. 1033-1039, 発行日 2009-05
ISSN
収録物識別子タイプ ISSN
収録物識別子 0740-3194
戻る
0
views
See details
Views