WEKO3
アイテム
Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion
https://repo.qst.go.jp/records/47392
https://repo.qst.go.jp/records/47392c5fb5482-d430-459b-a7ba-aa4ed4b704c6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-01-28 | |||||
タイトル | ||||||
タイトル | Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tachibana, Yasuhiko
× Tachibana, Yasuhiko× Obata, Takayuki× Inoue, Tomio× Aoki, Shigeki× al., et× 立花 泰彦× 小畠 隆行 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objectives: To compare the significance of the two-compartment model considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS). Methods: Diffusion-weighted images (9 b-values with 6 directions) were acquired from twelve healthy female volunteers (22 - 52 years old, median 33 years) and 13 female MS patients (24 - 48 years old, median 37 years). Diffusion parameters based on the two-compartment model of water diffusion considering diffusional anisotropy was calculated by a proposed method. Other parameters including diffusion tensor imaging and conventional apparent diffusion coefficient (ADC) were also obtained. They were compared statistically between the control and MS groups. Results: Diffusion of the slow diffusion compartment in a radial direction of neuron fibers was elevated in MS patients (0.121 x10-3mm2/sec) in comparison to control (0.100 x10- 3mm2/sec), the difference being significant (P = 0.001). The difference between the groups was not significant in other comparisons including conventional ADC and fractional anisotropy (FA) of diffusion tensor imaging. Conclusion: The proposed method was applicable to clinically acceptable small data. The parameters obtained by this method improved the detectability of occult changes in NAWM compared to the conventional methods. |
|||||
書誌情報 |
European Radiology 巻 25, 号 6, p. 1701-1707, 発行日 2015-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0938-7994 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25577520 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s00330-014-3572-4 |