ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Molecular imaging of mesothelioma by detection of manganese-superoxide dismutase activity using manganese-enhanced magnetic resonance imaging

https://repo.qst.go.jp/records/46031
https://repo.qst.go.jp/records/46031
1644718a-c425-402c-84ed-c589f2c64a1b
Item type 学術雑誌論文 / Journal Article(1)
公開日 2011-04-12
タイトル
タイトル Molecular imaging of mesothelioma by detection of manganese-superoxide dismutase activity using manganese-enhanced magnetic resonance imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Hasegawa, Sumitaka

× Hasegawa, Sumitaka

WEKO 458115

Hasegawa, Sumitaka

Search repository
Koshikawa, Michiko

× Koshikawa, Michiko

WEKO 458116

Koshikawa, Michiko

Search repository
Saito, Shigeyoshi

× Saito, Shigeyoshi

WEKO 458117

Saito, Shigeyoshi

Search repository
Morokoshi, Yukie

× Morokoshi, Yukie

WEKO 458118

Morokoshi, Yukie

Search repository
Furukawa, Takako

× Furukawa, Takako

WEKO 458119

Furukawa, Takako

Search repository
Aoki, Ichio

× Aoki, Ichio

WEKO 458120

Aoki, Ichio

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 458121

Saga, Tsuneo

Search repository
長谷川 純崇

× 長谷川 純崇

WEKO 458122

en 長谷川 純崇

Search repository
越川 道子

× 越川 道子

WEKO 458123

en 越川 道子

Search repository
齋藤 茂芳

× 齋藤 茂芳

WEKO 458124

en 齋藤 茂芳

Search repository
諸越 幸恵

× 諸越 幸恵

WEKO 458125

en 諸越 幸恵

Search repository
古川 高子

× 古川 高子

WEKO 458126

en 古川 高子

Search repository
青木 伊知男

× 青木 伊知男

WEKO 458127

en 青木 伊知男

Search repository
佐賀 恒夫

× 佐賀 恒夫

WEKO 458128

en 佐賀 恒夫

Search repository
抄録
内容記述タイプ Abstract
内容記述 Malignant mesothelioma (MM) is a fatal malignancy with a rapidly increasing incidence in industrialized countries because of the widespread use of asbestos in the past centuries. Early diagnosis of MM is critical for a better prognosis, but this is often difficult because of the lack of disease-specific diagnostic imaging. Here we report that manganese-enhanced magnetic resonance imaging (MEMRI) represents a promising approach for a more selective mesothelioma imaging by monitoring a high-level expression of manganese-superoxide dismutase (Mn-SOD), which is observed in many MM. We found that most human MM cells over-expressed Mn-SOD protein compared to human mesothelial cells, and that NCI-H226 human MM cells highly expressed Mn-SOD and augmented Mn accumulation when loaded with manganese chloride (MnCl(2)). The cells showed marked T(1)-signal enhancement on in vitro MRI after incubation with MnCl(2) because of the T(1) shortening effect of Mn(2+). H226 subcutaneous tumor was preferentially enhanced compared to a lung adenocarcinoma cell tumor and another human MM cell tumor in MnCl(2)-enhanced T(1)-weighted MR image (T(1)WI), correlating with their respective Mn-SOD expression levels. Moreover, in a more clinically relevant setting, H226 xenografted pleural tumor was markedly enhanced and readily detected by MEMRI using manganese dipyridoxyl diphosphate (MnDPDP), a clinically used contrast agent, as well as MnCl(2). Therefore, we propose that MEMRI can be a potentially powerful method for non-invasive detection of MM, with high spatial resolution and marked signal enhancement, by targeting Mn-SOD.
書誌情報 International Journal of Cancer

巻 128, 号 9, p. 2138-2146, 発行日 2010-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0020-7136
DOI
識別子タイプ DOI
関連識別子 10.1002/ijc.25547
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 23:56:41.286997
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3