Ultrafast LC Method for Purification and Metabolite Analysis of PET Probes.

https://repo.qst.go.jp/records/45725
https://repo.qst.go.jp/records/45725
f7e21e5c-b504-435c-bb8e-b052d02f3747
Item type 学術雑誌論文 / Journal Article(1)
公開日 2010-01-08
タイトル
タイトル Ultrafast LC Method for Purification and Metabolite Analysis of PET Probes.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nakao, Ryuji

× Nakao, Ryuji

WEKO 454501

Nakao, Ryuji

Search repository
Ito, Takehito

× Ito, Takehito

WEKO 454502

Ito, Takehito

Search repository
Hayashi, Kazutaka

× Hayashi, Kazutaka

WEKO 454503

Hayashi, Kazutaka

Search repository
Fukumura, Toshimitsu

× Fukumura, Toshimitsu

WEKO 454504

Fukumura, Toshimitsu

Search repository
Suzuki, Kazutoshi

× Suzuki, Kazutoshi

WEKO 454505

Suzuki, Kazutoshi

Search repository
中尾 隆士

× 中尾 隆士

WEKO 454506

en 中尾 隆士

Search repository
伊藤 岳人

× 伊藤 岳人

WEKO 454507

en 伊藤 岳人

Search repository
林 和孝

× 林 和孝

WEKO 454508

en 林 和孝

Search repository
福村 利光

× 福村 利光

WEKO 454509

en 福村 利光

Search repository
鈴木 和年

× 鈴木 和年

WEKO 454510

en 鈴木 和年

Search repository
抄録
内容記述タイプ Abstract
内容記述 An ultrafast and efficient high-performance liquid chromatographic (LC) method was developed to purify positron emission tomography (PET) radiopharmaceuticals as well as for metabolite analysis of the plasma sample. Chromatographic separation was achieved on a short (60 mm length) semipreparative (10 mm I.D.) column packed with 2.5-[mu]m particles using a mixture of acetonitrile and sodium phosphate buffer as the mobile phase at a flow rate of 8–10 ml/min. Under the optimum conditions, excellent separation of the target PET probe was obtained from chemical/radiochemical impurities or radioactive metabolites with a very short run time of 2 min. This characteristic enabled significant shortening of the purification and evaporation processes in the production of short-lived radiopharmaceuticals and highly sensitive radiometric analysis with good temporal resolution during the metabolism study.
書誌情報 Nuclear Medicine and Biology

巻 37, 号 1, p. 67-72, 発行日 2010-01
ISSN
収録物識別子タイプ ISSN
収録物識別子 0969-8051
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:00:23.095370
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3