{"created":"2023-05-15T14:35:33.602321+00:00","id":45725,"links":{},"metadata":{"_buckets":{"deposit":"63ade4ed-098e-4f99-a18a-6bdb5d865675"},"_deposit":{"created_by":1,"id":"45725","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"45725"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00045725","sets":["1"]},"author_link":["454508","454502","454509","454505","454504","454507","454503","454501","454506","454510"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2010-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"72","bibliographicPageStart":"67","bibliographicVolumeNumber":"37","bibliographic_titles":[{"bibliographic_title":"Nuclear Medicine and Biology"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"An ultrafast and efficient high-performance liquid chromatographic (LC) method was developed to purify positron emission tomography (PET) radiopharmaceuticals as well as for metabolite analysis of the plasma sample. Chromatographic separation was achieved on a short (60 mm length) semipreparative (10 mm I.D.) column packed with 2.5-[mu]m particles using a mixture of acetonitrile and sodium phosphate buffer as the mobile phase at a flow rate of 8–10 ml/min. Under the optimum conditions, excellent separation of the target PET probe was obtained from chemical/radiochemical impurities or radioactive metabolites with a very short run time of 2 min. This characteristic enabled significant shortening of the purification and evaporation processes in the production of short-lived radiopharmaceuticals and highly sensitive radiometric analysis with good temporal resolution during the metabolism study.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0969-8051","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Nakao, Ryuji"}],"nameIdentifiers":[{"nameIdentifier":"454501","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ito, Takehito"}],"nameIdentifiers":[{"nameIdentifier":"454502","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayashi, Kazutaka"}],"nameIdentifiers":[{"nameIdentifier":"454503","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fukumura, Toshimitsu"}],"nameIdentifiers":[{"nameIdentifier":"454504","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Suzuki, Kazutoshi"}],"nameIdentifiers":[{"nameIdentifier":"454505","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"中尾 隆士","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"454506","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"伊藤 岳人","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"454507","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"林 和孝","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"454508","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"福村 利光","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"454509","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"鈴木 和年","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"454510","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Ultrafast LC Method for Purification and Metabolite Analysis of PET Probes.","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Ultrafast LC Method for Purification and Metabolite Analysis of PET Probes."}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2010-01-08"},"publish_date":"2010-01-08","publish_status":"0","recid":"45725","relation_version_is_last":true,"title":["Ultrafast LC Method for Purification and Metabolite Analysis of PET Probes."],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:00:22.968243+00:00"}