ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Assessment of DNA damage in multiple organs of mice after whole body X-irradiation using the comet assay

https://repo.qst.go.jp/records/45304
https://repo.qst.go.jp/records/45304
3731fbbf-5eb0-44b5-a049-891e82525da7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-10-22
タイトル
タイトル Assessment of DNA damage in multiple organs of mice after whole body X-irradiation using the comet assay
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ueno, Shunji

× Ueno, Shunji

WEKO 450060

Ueno, Shunji

Search repository
Kashimoto, Takashige

× Kashimoto, Takashige

WEKO 450061

Kashimoto, Takashige

Search repository
Susa, Nobuyuki

× Susa, Nobuyuki

WEKO 450062

Susa, Nobuyuki

Search repository
Ito, Nobuhiko

× Ito, Nobuhiko

WEKO 450063

Ito, Nobuhiko

Search repository
Takeda, Shino

× Takeda, Shino

WEKO 450064

Takeda, Shino

Search repository
Nishimura, Yoshikazu

× Nishimura, Yoshikazu

WEKO 450065

Nishimura, Yoshikazu

Search repository
Sasaki, Yuf

× Sasaki, Yuf

WEKO 450066

Sasaki, Yuf

Search repository
Sugiyama, Masayasu

× Sugiyama, Masayasu

WEKO 450067

Sugiyama, Masayasu

Search repository
et.al

× et.al

WEKO 450068

et.al

Search repository
上野 俊治

× 上野 俊治

WEKO 450069

en 上野 俊治

Search repository
伊藤 伸彦

× 伊藤 伸彦

WEKO 450070

en 伊藤 伸彦

Search repository
武田 志乃

× 武田 志乃

WEKO 450071

en 武田 志乃

Search repository
西村 義一

× 西村 義一

WEKO 450072

en 西村 義一

Search repository
抄録
内容記述タイプ Abstract
内容記述 The comet assay was performed to elucidate the linearity of calibration curves and detection limits for DNA damage in multiple
organs of whole body X-irradiated mice, and rates of reduction in DNA damage by DNA repair during the irradiation period were
estimated in the respective organs by comparing the rates of increase in DNA damage at different absorbed dose rates of X-rays.
Of the assay parameters, tail length and the percentage DNA in the tail showed a higher sensitivity to DNA damage in most organs
than Olive tail moment. Data at the higher absorbed dose rates (2.22 or 1.44 Gy/min) showed good correlations between absorbed
doses and these two parameters, with correlation coefficients of more than 0.7 in many organs. However, this assay had difficulty
detecting DNA damage at the lower absorption dose rate (0.72 Gy/min). The estimated rates of increase in DNA damage and those
of DNA repair during the irradiation period in the respective organs suggested differences in the radiosensitivity of nuclear DNA
and DNA repair capacity among organs. Our results indicated that absorbed dose rates of 1.0–1.3 Gy/min or greater were needed to
induce detectable DNA damages by the comet assay in many organs.
書誌情報 Genetic Toxicology and Environmental Mutagenesis : A Section of Mutation Research

巻 634, 号 1/2, p. 135-145, 発行日 2007-12
ISSN
収録物識別子タイプ ISSN
収録物識別子 1383-5718
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:05:18.793975
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3