  1. 原著論文

Distribution volume as an alternative to the binding potential for sigma1receptor imaging

https://repo.qst.go.jp/records/45271
https://repo.qst.go.jp/records/45271
6baa54ee-4042-4f45-a41f-b48bec372a23
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-09-22
タイトル
タイトル Distribution volume as an alternative to the binding potential for sigma1receptor imaging
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kimura, Yuichi

× Kimura, Yuichi

WEKO 449698

Kimura, Yuichi

Search repository
Naganawa, Mika

× Naganawa, Mika

WEKO 449699

Naganawa, Mika

Search repository
Sakata, Muneyuki

× Sakata, Muneyuki

WEKO 449700

Sakata, Muneyuki

Search repository
Ishikawa, Masatomo

× Ishikawa, Masatomo

WEKO 449701

Ishikawa, Masatomo

Search repository
Mishina, Masahiro

× Mishina, Masahiro

WEKO 449702

Mishina, Masahiro

Search repository
Oda, Keiichi

× Oda, Keiichi

WEKO 449703

Oda, Keiichi

Search repository
Ishii, Kenji

× Ishii, Kenji

WEKO 449704

Ishii, Kenji

Search repository
Ishiwata, Kiichi

× Ishiwata, Kiichi

WEKO 449705

Ishiwata, Kiichi

Search repository
木村 裕一

× 木村 裕一

WEKO 449706

en 木村 裕一

Search repository
長縄 美香

× 長縄 美香

WEKO 449707

en 長縄 美香

Search repository
織田 圭一

× 織田 圭一

WEKO 449708

en 織田 圭一

Search repository
石井 賢二

× 石井 賢二

WEKO 449709

en 石井 賢二

Search repository
石渡 喜一

× 石渡 喜一

WEKO 449710

en 石渡 喜一

Search repository
抄録
内容記述タイプ Abstract
内容記述 The applicability of total distribution volume (DVt) as an alternative to binding potential (BP) was investigated for neuroreceptor mapping by positron emission tomography (PET). BP is defi ned as a representative quantity of receptor density. However, for making parametric images of BP, a reference region where an aimed receptor has a very low density is assumed to exist in a target region such as the brain. Thus, if the kinetics of a radioligand for target receptors does not permit an appropriate reference region, BP imaging is unattainable. In this study, [11C]SA4503 PET is taken to be considered which has a high affi nity to the sigma1 receptors. Through a clinical investigation using wide ranges of physiological situations, ages, sex, diseases, and selective drug-loading conditions, DVt has a
good linear relationship with BP, and the images can be used as a spatial stribution of sigma1 density.
書誌情報 Annals of Nuclear Medicine

巻 21, 号 9, p. 533-535, 発行日 2007-11
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-007-0063-6
戻る
0
views
See details
Views