  1. 原著論文

Shortened protocol in practical [11C] SA4503-PET studies for the sigma1 receptor quantification

https://repo.qst.go.jp/records/45160
https://repo.qst.go.jp/records/45160
e2895604-e5b7-40b8-89a0-2310a3090f27
Item type 学術雑誌論文 / Journal Article(1)
公開日 2008-05-16
タイトル
タイトル Shortened protocol in practical [11C] SA4503-PET studies for the sigma1 receptor quantification
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sakata, Muneyuki

× Sakata, Muneyuki

WEKO 448495

Sakata, Muneyuki

Search repository
Kimura, Yuichi

× Kimura, Yuichi

WEKO 448496

Kimura, Yuichi

Search repository
Naganawa, Mika

× Naganawa, Mika

WEKO 448497

Naganawa, Mika

Search repository
Ishikawa, Masatomo

× Ishikawa, Masatomo

WEKO 448498

Ishikawa, Masatomo

Search repository
Oda, Keiichi

× Oda, Keiichi

WEKO 448499

Oda, Keiichi

Search repository
Ishii, Kenji

× Ishii, Kenji

WEKO 448500

Ishii, Kenji

Search repository
Hashimoto, Kenji

× Hashimoto, Kenji

WEKO 448501

Hashimoto, Kenji

Search repository
Chihara, Kunihiro

× Chihara, Kunihiro

WEKO 448502

Chihara, Kunihiro

Search repository
Ishiwata, Kiichi

× Ishiwata, Kiichi

WEKO 448503

Ishiwata, Kiichi

Search repository
坂田 宗之

× 坂田 宗之

WEKO 448504

en 坂田 宗之

Search repository
木村 裕一

× 木村 裕一

WEKO 448505

en 木村 裕一

Search repository
長縄 美香

× 長縄 美香

WEKO 448506

en 長縄 美香

Search repository
織田 圭一

× 織田 圭一

WEKO 448507

en 織田 圭一

Search repository
石井 賢二

× 石井 賢二

WEKO 448508

en 石井 賢二

Search repository
橋本 謙二

× 橋本 謙二

WEKO 448509

en 橋本 謙二

Search repository
石渡 喜一

× 石渡 喜一

WEKO 448510

en 石渡 喜一

Search repository
抄録
内容記述タイプ Abstract
内容記述 In practical positron emission tomography(PET) diagnosis, a shortened protocol is preferred for patients with brain disorders. In this study, the applicability
of a shortened protocol as an alternative to the 90-min PET scan with [11C]SA4503 for quantitative sigma1 receptor measurement was investigated. Tissue time-activity curves of 288 regions of interest in the brain from 32 [11C]SA4503-PET scans of 16 healthy subjects prior to and following administration of a selective serotonin reuptake inhibitor (fluvoxamine or paroxetine) were applied to two algorithms of quantitative analysis; binding potential (BP) was derived from compartmental
analysis based on nonlinear estimation, and total distribution volume (tDV) was derived from Logan plot analysis.
As a result, although both BP and tDV tended to be underestimated by the shortened method, the estimates from the shortened protocol had good linear relationships with those of the full-length protocol. In conclusion, if approximately 10% differences in the estimated results are acceptable for a specific purpose, then
a 60-min measurement protocol is capable of providing reliable results.
書誌情報 Annals of Nuclear Medicine

巻 22, 号 2, p. 143-146, 発行日 2008-03
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-007-0088-x
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-16 00:06:57.843619
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3