Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron

https://repo.qst.go.jp/records/44748
https://repo.qst.go.jp/records/44748
0b6819df-8e03-4f8d-b1b3-6da1879d7414
Item type 学術雑誌論文 / Journal Article(1)
公開日 2006-12-25
タイトル
タイトル Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Honma, Toshihiro

× Honma, Toshihiro

WEKO 444269

Honma, Toshihiro

Search repository
Houjou, Satoru

× Houjou, Satoru

WEKO 444270

Houjou, Satoru

Search repository
Sakamoto, Yukio

× Sakamoto, Yukio

WEKO 444271

Sakamoto, Yukio

Search repository
Muramatsu, Masayuki

× Muramatsu, Masayuki

WEKO 444272

Muramatsu, Masayuki

Search repository
Miyahara, Nobuyuki

× Miyahara, Nobuyuki

WEKO 444273

Miyahara, Nobuyuki

Search repository
Yamada, Satoru

× Yamada, Satoru

WEKO 444274

Yamada, Satoru

Search repository
et.al

× et.al

WEKO 444275

et.al

Search repository
本間 壽廣

× 本間 壽廣

WEKO 444276

en 本間 壽廣

Search repository
北條 悟

× 北條 悟

WEKO 444277

en 北條 悟

Search repository
坂本 幸雄

× 坂本 幸雄

WEKO 444278

en 坂本 幸雄

Search repository
村松 正幸

× 村松 正幸

WEKO 444279

en 村松 正幸

Search repository
宮原 信幸

× 宮原 信幸

WEKO 444280

en 宮原 信幸

Search repository
山田 聰

× 山田 聰

WEKO 444281

en 山田 聰

Search repository
抄録
内容記述タイプ Abstract
内容記述 A low-energy ion decelerator for the acceleration-deceleration system has been designed and installed in the beam-injection line of the NIRS-930 cyclotron in an attempt to increase the beam intensity from the cyclotron. With this acceleration-deceleration system, the beam intensity of C-12(4+) ions at the cyclotron exit has been increased by about five times. The system has an advantage in that it allows us to extract a high-current ion beam from an electron cyclotron resonance ion source because, independently of the injection-energy matching to the cyclotron, a large potential difference can be applied between the source and the extractor. The voltage applied to the extractor is about -12 kV, which is reduced to the ground potential by the decelerator. The electric field distributions in the deceleration system were carefully designed using a three-dimensional field simulator. Design studies of the decelerator as well as the result of a beam test are presented.
書誌情報 Review of Scientific Instruments

巻 77, 号 3, p. 03B909-1-03B909-3, 発行日 2006-04
ISSN
収録物識別子タイプ ISSN
収録物識別子 0034-6748
戻る
0
views
See details
Views