{"created":"2023-05-15T14:34:37.625397+00:00","id":44748,"links":{},"metadata":{"_buckets":{"deposit":"062560a6-b6d1-4684-be89-c85035a91179"},"_deposit":{"created_by":1,"id":"44748","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"44748"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00044748","sets":["1"]},"author_link":["444277","444272","444273","444276","444274","444280","444271","444275","444270","444269","444278","444281","444279"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-04","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"03B909-3","bibliographicPageStart":"03B909-1","bibliographicVolumeNumber":"77","bibliographic_titles":[{"bibliographic_title":"Review of Scientific Instruments"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"A low-energy ion decelerator for the acceleration-deceleration system has been designed and installed in the beam-injection line of the NIRS-930 cyclotron in an attempt to increase the beam intensity from the cyclotron. With this acceleration-deceleration system, the beam intensity of C-12(4+) ions at the cyclotron exit has been increased by about five times. The system has an advantage in that it allows us to extract a high-current ion beam from an electron cyclotron resonance ion source because, independently of the injection-energy matching to the cyclotron, a large potential difference can be applied between the source and the extractor. The voltage applied to the extractor is about -12 kV, which is reduced to the ground potential by the decelerator. The electric field distributions in the deceleration system were carefully designed using a three-dimensional field simulator. Design studies of the decelerator as well as the result of a beam test are presented.","subitem_description_type":"Abstract"}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0034-6748","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Honma, Toshihiro"}],"nameIdentifiers":[{"nameIdentifier":"444269","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Houjou, Satoru"}],"nameIdentifiers":[{"nameIdentifier":"444270","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Sakamoto, Yukio"}],"nameIdentifiers":[{"nameIdentifier":"444271","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Muramatsu, Masayuki"}],"nameIdentifiers":[{"nameIdentifier":"444272","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Miyahara, Nobuyuki"}],"nameIdentifiers":[{"nameIdentifier":"444273","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yamada, Satoru"}],"nameIdentifiers":[{"nameIdentifier":"444274","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"et.al"}],"nameIdentifiers":[{"nameIdentifier":"444275","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"本間 壽廣","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444276","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"北條 悟","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444277","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"坂本 幸雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444278","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"村松 正幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444279","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"宮原 信幸","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444280","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山田 聰","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"444281","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2006-12-25"},"publish_date":"2006-12-25","publish_status":"0","recid":"44748","relation_version_is_last":true,"title":["Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-16T00:11:49.223115+00:00"}