WEKO3
アイテム
{"_buckets": {"deposit": "98197097-cca5-43eb-8bbc-f184fb38d35e"}, "_deposit": {"created_by": 1, "id": "85430", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "85430"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00085430", "sets": ["1"]}, "author_link": ["1029447", "1029446", "1029449", "1029445", "1029451", "1029450", "1029448"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2021-12", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "12", "bibliographicPageEnd": "1769", "bibliographicPageStart": "1765-1769", "bibliographicVolumeNumber": "37", "bibliographic_titles": [{"bibliographic_title": "Analytical sciences : the international journal of the Japan Society for Analytical Chemistry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Glucose sensors for NMR relaxometry and magnetic resonance imaging (MRI) can be used for the direct measurement of glucose in turbid biological specimens. Here, we proposed a magnetic glucose sensor based on superparamagnetic iron oxide (SPIO) nanoparticles conjugated to a mannopyranoside derivative and concanavalin A (ConA). The binding of mannopyranoside groups to ConA produced a nanoparticle cluster that was dissociated by competitive binding of glucose to ConA, resulting in changes in the transverse relaxation time (T) in a glucose-dependent manner. The sensor gave rise to significant T changes in physiological glucose levels of 3 - 8 mM at a nanoparticle concentration of 0.5 nM. Significant T responses were observed within 6 min of 5 mM glucose detection. Sensor-based MRI by a benchtop 1 tesla scanner permitted a measurement of multiple samples within 8 min. These results demonstrate that the relaxometric glucose sensor could lead to high throughput direct assay of blood samples by using a compact MRI scanner for point-of-care testing.", "subitem_description_type": "Abstract"}]}, "item_8_publisher_8": {"attribute_name": "出版者", "attribute_value_mlt": [{"subitem_publisher": "Japan Society For Analytical Chemistry"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "34248090", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.2116/analsci.21P082", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://www.jstage.jst.go.jp/article/analsci/37/12/37_21P082/_article/-char/ja/", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0910-6340", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Okada, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "1029445", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takayasu, Satoko"}], "nameIdentifiers": [{"nameIdentifier": "1029446", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sumiyoshi, Akira"}], "nameIdentifiers": [{"nameIdentifier": "1029447", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Ichio"}], "nameIdentifiers": [{"nameIdentifier": "1029448", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nakamura, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "1029449", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Akira, Sumiyoshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1029450", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ichio, Aoki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "1029451", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors.", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors."}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/85430", "pubdate": {"attribute_name": "公開日", "attribute_value": "2021-12-23"}, "publish_date": "2021-12-23", "publish_status": "0", "recid": "85430", "relation": {}, "relation_version_is_last": true, "title": ["MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors."], "weko_shared_id": -1}
MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors.
https://repo.qst.go.jp/records/85430
https://repo.qst.go.jp/records/85430e7cf6cf2-5da7-430d-b7a4-3f6d1f6edc5a
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-12-23 | |||||
タイトル | ||||||
タイトル | MRI-based Glucose Assay Using Magnetic Nanoparticle Sensors. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Okada, Satoshi
× Okada, Satoshi× Takayasu, Satoko× Sumiyoshi, Akira× Aoki, Ichio× Nakamura, Hiroyuki× Akira, Sumiyoshi× Ichio, Aoki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Glucose sensors for NMR relaxometry and magnetic resonance imaging (MRI) can be used for the direct measurement of glucose in turbid biological specimens. Here, we proposed a magnetic glucose sensor based on superparamagnetic iron oxide (SPIO) nanoparticles conjugated to a mannopyranoside derivative and concanavalin A (ConA). The binding of mannopyranoside groups to ConA produced a nanoparticle cluster that was dissociated by competitive binding of glucose to ConA, resulting in changes in the transverse relaxation time (T) in a glucose-dependent manner. The sensor gave rise to significant T changes in physiological glucose levels of 3 - 8 mM at a nanoparticle concentration of 0.5 nM. Significant T responses were observed within 6 min of 5 mM glucose detection. Sensor-based MRI by a benchtop 1 tesla scanner permitted a measurement of multiple samples within 8 min. These results demonstrate that the relaxometric glucose sensor could lead to high throughput direct assay of blood samples by using a compact MRI scanner for point-of-care testing. | |||||
書誌情報 |
Analytical sciences : the international journal of the Japan Society for Analytical Chemistry 巻 37, 号 12, p. 1765-1769-1769, 発行日 2021-12 |
|||||
出版者 | ||||||
出版者 | Japan Society For Analytical Chemistry | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0910-6340 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34248090 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.2116/analsci.21P082 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://www.jstage.jst.go.jp/article/analsci/37/12/37_21P082/_article/-char/ja/ |