{"_buckets": {"deposit": "f0773e67-f19e-48a1-b49c-12fd494a213a"}, "_deposit": {"created_by": 1, "id": "80537", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80537"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080537", "sets": ["28"]}, "author_link": ["889536", "889530", "889540", "889535", "889532", "889534", "889531", "889539", "889538", "889533", "889537"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2020-09-16", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "We present a design overview of the beam diagnostic system for the new 3 GeV light source being constructed in Tohoku, Japan, and some test results obtained at SPring-8. This light source will generate brilliant x-rays from a high-quality electron beam having 1 nm rad emittance and 400 mA maximum stored current. To achieve the design performance and stability, we must monitor various beam parameters precisely. The beam position should be detected precisely: single-pass resolution \u003c 0.1 mm (0.1 nC injected beam), COD resolution \u003c 0.1 μm (more than 100 mA stored current), position stability \u003c 5 μm for 1 month. We will use 112 button-type BPMs in the storage ring for these purposes. The stored beam current and beam size are also monitored with a DCCT and an x-ray pinhole camera. We will install a 3-pole wiggler to a straight section for the pinhole camera and other optical diagnostics. A stripline BPM and a stripline kicker will be installed to another straight section to suppress the beam instability and to measure betatron tune. We will use FPGA-based high-speed electronics for instability suppression with a bunch-by-bunch feedback method and real-time tune monitoring.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "IBIC 2020 - 9th International Beam Instrumentation Conference", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "前坂, 比呂和"}], "nameIdentifiers": [{"nameIdentifier": "889530", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "福井, 達"}], "nameIdentifiers": [{"nameIdentifier": "889531", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "出羽, 秀樹"}], "nameIdentifiers": [{"nameIdentifier": "889532", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "藤田, 貴弘"}], "nameIdentifiers": [{"nameIdentifier": "889533", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "正木, 満博"}], "nameIdentifiers": [{"nameIdentifier": "889534", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高野, 史郎"}], "nameIdentifiers": [{"nameIdentifier": "889535", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "上島, 考太"}], "nameIdentifiers": [{"nameIdentifier": "889536", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujita, Takahiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "889537", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Masaki, Mitsuhiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "889538", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Takano, Shiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "889539", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ueshima, Kouta", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "889540", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Design of the Beam Diagnostic System for the New 3GeV Light Source in Japan", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Design of the Beam Diagnostic System for the New 3GeV Light Source in Japan"}]}, "item_type_id": "10005", "owner": "1", "path": ["28"], "permalink_uri": "https://repo.qst.go.jp/records/80537", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-01"}, "publish_date": "2020-09-01", "publish_status": "0", "recid": "80537", "relation": {}, "relation_version_is_last": true, "title": ["Design of the Beam Diagnostic System for the New 3GeV Light Source in Japan"], "weko_shared_id": -1}
Design of the Beam Diagnostic System for the New 3GeV Light Source in Japan
https://repo.qst.go.jp/records/80537
https://repo.qst.go.jp/records/8053731d91221-ddfa-496d-a9f5-46a6734b0257
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-01 | |||||
タイトル | ||||||
タイトル | Design of the Beam Diagnostic System for the New 3GeV Light Source in Japan | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
前坂, 比呂和
× 前坂, 比呂和× 福井, 達× 出羽, 秀樹× 藤田, 貴弘× 正木, 満博× 高野, 史郎× 上島, 考太× Fujita, Takahiro× Masaki, Mitsuhiro× Takano, Shiro× Ueshima, Kouta |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | We present a design overview of the beam diagnostic system for the new 3 GeV light source being constructed in Tohoku, Japan, and some test results obtained at SPring-8. This light source will generate brilliant x-rays from a high-quality electron beam having 1 nm rad emittance and 400 mA maximum stored current. To achieve the design performance and stability, we must monitor various beam parameters precisely. The beam position should be detected precisely: single-pass resolution < 0.1 mm (0.1 nC injected beam), COD resolution < 0.1 μm (more than 100 mA stored current), position stability < 5 μm for 1 month. We will use 112 button-type BPMs in the storage ring for these purposes. The stored beam current and beam size are also monitored with a DCCT and an x-ray pinhole camera. We will install a 3-pole wiggler to a straight section for the pinhole camera and other optical diagnostics. A stripline BPM and a stripline kicker will be installed to another straight section to suppress the beam instability and to measure betatron tune. We will use FPGA-based high-speed electronics for instability suppression with a bunch-by-bunch feedback method and real-time tune monitoring. | |||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | IBIC 2020 - 9th International Beam Instrumentation Conference | |||||
発表年月日 | ||||||
日付 | 2020-09-16 | |||||
日付タイプ | Issued |