{"_buckets": {"deposit": "ca7dd561-8816-4706-83b1-f039f0a8a739"}, "_deposit": {"created_by": 1, "id": "54941", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "54941"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00054941", "sets": ["2"]}, "author_link": ["561846", "561849", "561845", "561850", "561851", "561848", "561847", "561852"], "item_10003_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-09", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "79", "bibliographicPageStart": "79", "bibliographicVolumeNumber": "38", "bibliographic_titles": [{"bibliographic_title": "医学物理"}]}]}, "item_10003_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "目的:高速モンテカルロ法であるfast dose calculator(FDC)により求められた線量とLETを用いてRBEを計算し、最先端陽子線治療であるIMPTに対して線量評価を行う。\n方法:腫瘍周辺をリスク臓器が覆うような脳腫瘍症例を選択した。その症例に対して、Eclipse治療計画装置を用いて、IMPTを計画した。ここで、その治療計画に対して、Yepseらが開発したFDCにより計算を実施し、線量やLETを求めた。FDCは、水に対して事前にGEANTシミュレーションを行っておいて、その結果を使って、任意の物質に対しては、長さや散乱角をスケーリングすることで、線量計算を行う方法で、計算時間は患者当たり5分と短い。そして、FDCにより計算された線量やLETに加え、組織パラメータを関数とするWilkensらによって開発されたRBE計算モデルを用いて線量計算を実施した。なお、各部位毎のRBEを計算するために、Freseらによって与えられた生物パラメータを用いた。このようにして計算されたCTVやリスク臓器における線量について、従来のRBE=1.1としたfixed RBEによる線量計算結果と比較した。\n結果:GTVやCTVにおいてvariable RBEは、fix RBEに比べて、最小線量と最大線量に対する線量は、約2%程度高かった。一方、脳幹の最小線量では、128%の線量差が観測されたが、最大線量では、2%であった。また、右視神経では、最小線量の差は40%で、最大線量の差は19%であった。\n結論:IMPT治療計画に対して、FDCにより線量計算を実施し、Wilkensらによって開発されたRBE計算モデルを用いてRBE計算を実行した。RBE計算の違いによるGTVやCTVにおける線量差は、2%程度であったが、部位によっては、最小線量の差が大きく出ることがわかった。", "subitem_description_type": "Abstract"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "河野, 良介"}], "nameIdentifiers": [{"nameIdentifier": "561845", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Wenhua, Cao"}], "nameIdentifiers": [{"nameIdentifier": "561846", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Pablo, Yepes"}], "nameIdentifiers": [{"nameIdentifier": "561847", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Xuemin, Bai"}], "nameIdentifiers": [{"nameIdentifier": "561848", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Falk, Poenisch"}], "nameIdentifiers": [{"nameIdentifier": "561849", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "David, R Grosshans"}], "nameIdentifiers": [{"nameIdentifier": "561850", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "秋元哲夫"}], "nameIdentifiers": [{"nameIdentifier": "561851", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "河野 良介", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "561852", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference paper", "resourceuri": "http://purl.org/coar/resource_type/c_5794"}]}, "item_title": "IMPTにおけるvariable RBE計算による線量評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "IMPTにおけるvariable RBE計算による線量評価"}]}, "item_type_id": "10003", "owner": "1", "path": ["2"], "permalink_uri": "https://repo.qst.go.jp/records/54941", "pubdate": {"attribute_name": "公開日", "attribute_value": "2018-12-21"}, "publish_date": "2018-12-21", "publish_status": "0", "recid": "54941", "relation": {}, "relation_version_is_last": true, "title": ["IMPTにおけるvariable RBE計算による線量評価"], "weko_shared_id": -1}
IMPTにおけるvariable RBE計算による線量評価
https://repo.qst.go.jp/records/54941
https://repo.qst.go.jp/records/54941173ebe4a-5e10-4927-83da-ac59f5d15a9d
Item type | 会議発表論文 / Conference Paper(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2018-12-21 | |||||
タイトル | ||||||
タイトル | IMPTにおけるvariable RBE計算による線量評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_5794 | |||||
資源タイプ | conference paper | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
河野, 良介
× 河野, 良介× Wenhua, Cao× Pablo, Yepes× Xuemin, Bai× Falk, Poenisch× David, R Grosshans× 秋元哲夫× 河野 良介 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 目的:高速モンテカルロ法であるfast dose calculator(FDC)により求められた線量とLETを用いてRBEを計算し、最先端陽子線治療であるIMPTに対して線量評価を行う。 方法:腫瘍周辺をリスク臓器が覆うような脳腫瘍症例を選択した。その症例に対して、Eclipse治療計画装置を用いて、IMPTを計画した。ここで、その治療計画に対して、Yepseらが開発したFDCにより計算を実施し、線量やLETを求めた。FDCは、水に対して事前にGEANTシミュレーションを行っておいて、その結果を使って、任意の物質に対しては、長さや散乱角をスケーリングすることで、線量計算を行う方法で、計算時間は患者当たり5分と短い。そして、FDCにより計算された線量やLETに加え、組織パラメータを関数とするWilkensらによって開発されたRBE計算モデルを用いて線量計算を実施した。なお、各部位毎のRBEを計算するために、Freseらによって与えられた生物パラメータを用いた。このようにして計算されたCTVやリスク臓器における線量について、従来のRBE=1.1としたfixed RBEによる線量計算結果と比較した。 結果:GTVやCTVにおいてvariable RBEは、fix RBEに比べて、最小線量と最大線量に対する線量は、約2%程度高かった。一方、脳幹の最小線量では、128%の線量差が観測されたが、最大線量では、2%であった。また、右視神経では、最小線量の差は40%で、最大線量の差は19%であった。 結論:IMPT治療計画に対して、FDCにより線量計算を実施し、Wilkensらによって開発されたRBE計算モデルを用いてRBE計算を実行した。RBE計算の違いによるGTVやCTVにおける線量差は、2%程度であったが、部位によっては、最小線量の差が大きく出ることがわかった。 |
|||||
書誌情報 |
医学物理 巻 38, 号 3, p. 79-79, 発行日 2018-09 |