{"created":"2023-05-15T14:40:02.176825+00:00","id":54941,"links":{},"metadata":{"_buckets":{"deposit":"ca7dd561-8816-4706-83b1-f039f0a8a739"},"_deposit":{"created_by":1,"id":"54941","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"54941"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00054941","sets":["2"]},"author_link":["561846","561849","561845","561850","561851","561848","561847","561852"],"item_10003_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-09","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"3","bibliographicPageEnd":"79","bibliographicPageStart":"79","bibliographicVolumeNumber":"38","bibliographic_titles":[{"bibliographic_title":"医学物理"}]}]},"item_10003_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"目的:高速モンテカルロ法であるfast dose calculator(FDC)により求められた線量とLETを用いてRBEを計算し、最先端陽子線治療であるIMPTに対して線量評価を行う。\n方法:腫瘍周辺をリスク臓器が覆うような脳腫瘍症例を選択した。その症例に対して、Eclipse治療計画装置を用いて、IMPTを計画した。ここで、その治療計画に対して、Yepseらが開発したFDCにより計算を実施し、線量やLETを求めた。FDCは、水に対して事前にGEANTシミュレーションを行っておいて、その結果を使って、任意の物質に対しては、長さや散乱角をスケーリングすることで、線量計算を行う方法で、計算時間は患者当たり5分と短い。そして、FDCにより計算された線量やLETに加え、組織パラメータを関数とするWilkensらによって開発されたRBE計算モデルを用いて線量計算を実施した。なお、各部位毎のRBEを計算するために、Freseらによって与えられた生物パラメータを用いた。このようにして計算されたCTVやリスク臓器における線量について、従来のRBE=1.1としたfixed RBEによる線量計算結果と比較した。\n結果:GTVやCTVにおいてvariable RBEは、fix RBEに比べて、最小線量と最大線量に対する線量は、約2%程度高かった。一方、脳幹の最小線量では、128%の線量差が観測されたが、最大線量では、2%であった。また、右視神経では、最小線量の差は40%で、最大線量の差は19%であった。\n結論:IMPT治療計画に対して、FDCにより線量計算を実施し、Wilkensらによって開発されたRBE計算モデルを用いてRBE計算を実行した。RBE計算の違いによるGTVやCTVにおける線量差は、2%程度であったが、部位によっては、最小線量の差が大きく出ることがわかった。","subitem_description_type":"Abstract"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"河野, 良介"}],"nameIdentifiers":[{"nameIdentifier":"561845","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Wenhua, Cao"}],"nameIdentifiers":[{"nameIdentifier":"561846","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Pablo, Yepes"}],"nameIdentifiers":[{"nameIdentifier":"561847","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Xuemin, Bai"}],"nameIdentifiers":[{"nameIdentifier":"561848","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Falk, Poenisch"}],"nameIdentifiers":[{"nameIdentifier":"561849","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"David, R Grosshans"}],"nameIdentifiers":[{"nameIdentifier":"561850","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"秋元哲夫"}],"nameIdentifiers":[{"nameIdentifier":"561851","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"河野 良介","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"561852","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference paper","resourceuri":"http://purl.org/coar/resource_type/c_5794"}]},"item_title":"IMPTにおけるvariable RBE計算による線量評価","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"IMPTにおけるvariable RBE計算による線量評価"}]},"item_type_id":"10003","owner":"1","path":["2"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-12-21"},"publish_date":"2018-12-21","publish_status":"0","recid":"54941","relation_version_is_last":true,"title":["IMPTにおけるvariable RBE計算による線量評価"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T22:55:09.121080+00:00"}