WEKO3
アイテム
{"_buckets": {"deposit": "947da820-1314-4493-b799-17806bbf8a8b"}, "_deposit": {"created_by": 1, "id": "47392", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "47392"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00047392", "sets": ["1"]}, "author_link": ["474456", "474460", "474457", "474458", "474462", "474459", "474461"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2015-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "6", "bibliographicPageEnd": "1707", "bibliographicPageStart": "1701", "bibliographicVolumeNumber": "25", "bibliographic_titles": [{"bibliographic_title": "European Radiology"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Objectives:\nTo compare the significance of the two-compartment model considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS).\nMethods:\nDiffusion-weighted images (9 b-values with 6 directions) were acquired from twelve healthy female volunteers (22 - 52 years old, median 33 years) and 13 female MS patients (24 - 48 years old, median 37 years). Diffusion parameters based on the two-compartment model of water diffusion considering diffusional anisotropy was calculated by a proposed method. Other parameters including diffusion tensor imaging and conventional apparent diffusion coefficient (ADC) were also obtained. They were compared statistically between the control and MS groups.\nResults:\nDiffusion of the slow diffusion compartment in a radial direction of neuron fibers was elevated in MS patients (0.121 x10-3mm2/sec) in comparison to control (0.100 x10- 3mm2/sec), the difference being significant (P = 0.001). The difference between the groups was not significant in other comparisons including conventional ADC and fractional anisotropy (FA) of diffusion tensor imaging.\nConclusion:\nThe proposed method was applicable to clinically acceptable small data. The parameters obtained by this method improved the detectability of occult changes in NAWM compared to the conventional methods.", "subitem_description_type": "Abstract"}]}, "item_8_relation_13": {"attribute_name": "PubMed番号", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "25577520", "subitem_relation_type_select": "PMID"}}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1007/s00330-014-3572-4", "subitem_relation_type_select": "DOI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0938-7994", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Tachibana, Yasuhiko"}], "nameIdentifiers": [{"nameIdentifier": "474456", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Obata, Takayuki"}], "nameIdentifiers": [{"nameIdentifier": "474457", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inoue, Tomio"}], "nameIdentifiers": [{"nameIdentifier": "474458", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Shigeki"}], "nameIdentifiers": [{"nameIdentifier": "474459", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "al., et"}], "nameIdentifiers": [{"nameIdentifier": "474460", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "立花 泰彦", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474461", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小畠 隆行", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "474462", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/47392", "pubdate": {"attribute_name": "公開日", "attribute_value": "2016-01-28"}, "publish_date": "2016-01-28", "publish_status": "0", "recid": "47392", "relation": {}, "relation_version_is_last": true, "title": ["Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion"], "weko_shared_id": -1}
Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion
https://repo.qst.go.jp/records/47392
https://repo.qst.go.jp/records/47392c5fb5482-d430-459b-a7ba-aa4ed4b704c6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2016-01-28 | |||||
タイトル | ||||||
タイトル | Analysis of normal-appearing white matter of multiple sclerosis by tensor-based two-compartment model of water diffusion | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Tachibana, Yasuhiko
× Tachibana, Yasuhiko× Obata, Takayuki× Inoue, Tomio× Aoki, Shigeki× al., et× 立花 泰彦× 小畠 隆行 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objectives: To compare the significance of the two-compartment model considering diffusional anisotropy with conventional diffusion analyzing methods regarding the detection of occult changes in normal-appearing white matter (NAWM) of multiple sclerosis (MS). Methods: Diffusion-weighted images (9 b-values with 6 directions) were acquired from twelve healthy female volunteers (22 - 52 years old, median 33 years) and 13 female MS patients (24 - 48 years old, median 37 years). Diffusion parameters based on the two-compartment model of water diffusion considering diffusional anisotropy was calculated by a proposed method. Other parameters including diffusion tensor imaging and conventional apparent diffusion coefficient (ADC) were also obtained. They were compared statistically between the control and MS groups. Results: Diffusion of the slow diffusion compartment in a radial direction of neuron fibers was elevated in MS patients (0.121 x10-3mm2/sec) in comparison to control (0.100 x10- 3mm2/sec), the difference being significant (P = 0.001). The difference between the groups was not significant in other comparisons including conventional ADC and fractional anisotropy (FA) of diffusion tensor imaging. Conclusion: The proposed method was applicable to clinically acceptable small data. The parameters obtained by this method improved the detectability of occult changes in NAWM compared to the conventional methods. |
|||||
書誌情報 |
European Radiology 巻 25, 号 6, p. 1701-1707, 発行日 2015-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0938-7994 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 25577520 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s00330-014-3572-4 |