WEKO3
アイテム
{"_buckets": {"deposit": "c135e784-a497-47ad-986f-7f631db9d9e2"}, "_deposit": {"created_by": 1, "id": "44878", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44878"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044878", "sets": ["1"]}, "author_link": ["445734", "445736", "445738", "445733", "445735", "445737", "445731", "445739", "445732", "445740"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2007-01", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "1-4", "bibliographicPageEnd": "194", "bibliographicPageStart": "188", "bibliographicVolumeNumber": "122", "bibliographic_titles": [{"bibliographic_title": "Radiation Protection Dosimetry"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "This study aims to clarify the enhancement effect on chromosomal aberrations via selective energy absorption by Cu atoms incultured bone cancer cells with non-labelled Cu-pyruvaldehyde-bis(N4-methylsemicarbazone) (Cu-PTSM) and monochromatic X rays. The X rays having the energy of the Cu K-shell absorption edge arising from synchrotron radiation (KEK-PF) was used as radiation source. Cu-PTSM labeled with copper radionuclides has been developed for medical imaging using positron emission tomography (PET). Evidence clearly showed that the absorption of X rays in the Cu K-shell caused this enhancement. After cells were treated with 1000 nM Cu-PTSM, the enhancement ratio of the initial yield of isochromatid breaks caused by CuK-H X-ray irradiation to that by 200 kVp X rays was 2.8. About 5.6 times of the remaining isochromatid breaks were observed at 4 h in Cu-PTSM treated samples irradiated with CuK-H X rays comparing to thatwith 200 kVp X rays. In this study, uniqueness in physical property such as Cu atom K-shell ionisation was applied for the enhancement of biological effects in cancer cells.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0144-8420", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Takakura, Kaoru"}], "nameIdentifiers": [{"nameIdentifier": "445731", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yaguchi, Satoshi"}], "nameIdentifiers": [{"nameIdentifier": "445732", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kanasugi, Yuuichi"}], "nameIdentifiers": [{"nameIdentifier": "445733", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kobayashi, Katsumi"}], "nameIdentifiers": [{"nameIdentifier": "445734", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Okayasu, Ryuichi"}], "nameIdentifiers": [{"nameIdentifier": "445735", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujibayashi, Yasuhisa"}], "nameIdentifiers": [{"nameIdentifier": "445736", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高倉 かほる", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445737", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "金杉 勇一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445738", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "小林 克己", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445739", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "岡安 隆一", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "445740", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "ENHANCEMENT OF CHROMOSOMAL ABERRATIONS IN TUMOR CELLS WITH A NON-LABELED CU-PTSM AND IRRADIATION WITH CU K-SHELL MONOCHOROMATIC X RAYS", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "ENHANCEMENT OF CHROMOSOMAL ABERRATIONS IN TUMOR CELLS WITH A NON-LABELED CU-PTSM AND IRRADIATION WITH CU K-SHELL MONOCHOROMATIC X RAYS"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44878", "pubdate": {"attribute_name": "公開日", "attribute_value": "2007-06-13"}, "publish_date": "2007-06-13", "publish_status": "0", "recid": "44878", "relation": {}, "relation_version_is_last": true, "title": ["ENHANCEMENT OF CHROMOSOMAL ABERRATIONS IN TUMOR CELLS WITH A NON-LABELED CU-PTSM AND IRRADIATION WITH CU K-SHELL MONOCHOROMATIC X RAYS"], "weko_shared_id": -1}
ENHANCEMENT OF CHROMOSOMAL ABERRATIONS IN TUMOR CELLS WITH A NON-LABELED CU-PTSM AND IRRADIATION WITH CU K-SHELL MONOCHOROMATIC X RAYS
https://repo.qst.go.jp/records/44878
https://repo.qst.go.jp/records/44878b5cd965f-1368-4be0-ae18-ccad6fcf506c
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2007-06-13 | |||||
タイトル | ||||||
タイトル | ENHANCEMENT OF CHROMOSOMAL ABERRATIONS IN TUMOR CELLS WITH A NON-LABELED CU-PTSM AND IRRADIATION WITH CU K-SHELL MONOCHOROMATIC X RAYS | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Takakura, Kaoru
× Takakura, Kaoru× Yaguchi, Satoshi× Kanasugi, Yuuichi× Kobayashi, Katsumi× Okayasu, Ryuichi× Fujibayashi, Yasuhisa× 高倉 かほる× 金杉 勇一× 小林 克己× 岡安 隆一 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | This study aims to clarify the enhancement effect on chromosomal aberrations via selective energy absorption by Cu atoms incultured bone cancer cells with non-labelled Cu-pyruvaldehyde-bis(N4-methylsemicarbazone) (Cu-PTSM) and monochromatic X rays. The X rays having the energy of the Cu K-shell absorption edge arising from synchrotron radiation (KEK-PF) was used as radiation source. Cu-PTSM labeled with copper radionuclides has been developed for medical imaging using positron emission tomography (PET). Evidence clearly showed that the absorption of X rays in the Cu K-shell caused this enhancement. After cells were treated with 1000 nM Cu-PTSM, the enhancement ratio of the initial yield of isochromatid breaks caused by CuK-H X-ray irradiation to that by 200 kVp X rays was 2.8. About 5.6 times of the remaining isochromatid breaks were observed at 4 h in Cu-PTSM treated samples irradiated with CuK-H X rays comparing to thatwith 200 kVp X rays. In this study, uniqueness in physical property such as Cu atom K-shell ionisation was applied for the enhancement of biological effects in cancer cells. | |||||
書誌情報 |
Radiation Protection Dosimetry 巻 122, 号 1-4, p. 188-194, 発行日 2007-01 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0144-8420 |