{"_buckets": {"deposit": "062560a6-b6d1-4684-be89-c85035a91179"}, "_deposit": {"created_by": 1, "id": "44748", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "44748"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00044748", "sets": ["1"]}, "author_link": ["444277", "444272", "444273", "444276", "444274", "444280", "444271", "444275", "444270", "444269", "444278", "444281", "444279"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2006-04", "bibliographicIssueDateType": "Issued"}, "bibliographicIssueNumber": "3", "bibliographicPageEnd": "03B909-3", "bibliographicPageStart": "03B909-1", "bibliographicVolumeNumber": "77", "bibliographic_titles": [{"bibliographic_title": "Review of Scientific Instruments"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "A low-energy ion decelerator for the acceleration-deceleration system has been designed and installed in the beam-injection line of the NIRS-930 cyclotron in an attempt to increase the beam intensity from the cyclotron. With this acceleration-deceleration system, the beam intensity of C-12(4+) ions at the cyclotron exit has been increased by about five times. The system has an advantage in that it allows us to extract a high-current ion beam from an electron cyclotron resonance ion source because, independently of the injection-energy matching to the cyclotron, a large potential difference can be applied between the source and the extractor. The voltage applied to the extractor is about -12 kV, which is reduced to the ground potential by the decelerator. The electric field distributions in the deceleration system were carefully designed using a three-dimensional field simulator. Design studies of the decelerator as well as the result of a beam test are presented.", "subitem_description_type": "Abstract"}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0034-6748", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Honma, Toshihiro"}], "nameIdentifiers": [{"nameIdentifier": "444269", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Houjou, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "444270", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakamoto, Yukio"}], "nameIdentifiers": [{"nameIdentifier": "444271", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Muramatsu, Masayuki"}], "nameIdentifiers": [{"nameIdentifier": "444272", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Miyahara, Nobuyuki"}], "nameIdentifiers": [{"nameIdentifier": "444273", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yamada, Satoru"}], "nameIdentifiers": [{"nameIdentifier": "444274", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "et.al"}], "nameIdentifiers": [{"nameIdentifier": "444275", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "本間 壽廣", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444276", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "北條 悟", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444277", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "坂本 幸雄", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444278", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "村松 正幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444279", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "宮原 信幸", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444280", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "山田 聰", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "444281", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/44748", "pubdate": {"attribute_name": "公開日", "attribute_value": "2006-12-25"}, "publish_date": "2006-12-25", "publish_status": "0", "recid": "44748", "relation": {}, "relation_version_is_last": true, "title": ["Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron"], "weko_shared_id": -1}
Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron
https://repo.qst.go.jp/records/44748
https://repo.qst.go.jp/records/447480b6819df-8e03-4f8d-b1b3-6da1879d7414
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2006-12-25 | |||||
タイトル | ||||||
タイトル | Low-energy ion decelerator for an external injection line at the NIRS-930 cyclotron | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Honma, Toshihiro
× Honma, Toshihiro× Houjou, Satoru× Sakamoto, Yukio× Muramatsu, Masayuki× Miyahara, Nobuyuki× Yamada, Satoru× et.al× 本間 壽廣× 北條 悟× 坂本 幸雄× 村松 正幸× 宮原 信幸× 山田 聰 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | A low-energy ion decelerator for the acceleration-deceleration system has been designed and installed in the beam-injection line of the NIRS-930 cyclotron in an attempt to increase the beam intensity from the cyclotron. With this acceleration-deceleration system, the beam intensity of C-12(4+) ions at the cyclotron exit has been increased by about five times. The system has an advantage in that it allows us to extract a high-current ion beam from an electron cyclotron resonance ion source because, independently of the injection-energy matching to the cyclotron, a large potential difference can be applied between the source and the extractor. The voltage applied to the extractor is about -12 kV, which is reduced to the ground potential by the decelerator. The electric field distributions in the deceleration system were carefully designed using a three-dimensional field simulator. Design studies of the decelerator as well as the result of a beam test are presented. | |||||