Results of ITER TF coil double pancake heat treatment in Japan
https://repo.qst.go.jp/records/85011
https://repo.qst.go.jp/records/850119a878af6-bd64-4bdb-b34f-51c1a7b93cdb
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-02-07 | |||||
タイトル | ||||||
タイトル | Results of ITER TF coil double pancake heat treatment in Japan | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Hideki, Kajitani
× Hideki, Kajitani× Mio, Nakamoto× Yoshizawa, Kazumi× Yasuhiro, Uno× Tsutomu, Kawasaki× Kunihiro, Matsui× Norikiyo, Koizumi× Masataka, Nakahira× Hideki, Kajitani× Mio, Nakamoto× Yoshizawa, Kazumi× Yasuhiro, Uno× Tsutomu, Kawasaki× Kunihiro, Matsui× Norikiyo, Koizumi× Masataka, Nakahira |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | In Japan, 9 ITER TF coils were manufactured for the ITER project. Each TF coil consists of seven Nb3Sn conductor double pancakes (DPs). In DP manufacturing, heat treatment is one of the most important processes, because the insertion of a heat treated conductor into the radial plate groove (i.e., transfer) is complicated owing to the elongation of the conductor under heat treatment. A critical current distribution over the DP may also occur owing to the temperature distribution and disturbance in the heat treatment process. To address these issues, this study developed a procedure wherein the conductor length elongation caused by heat treatment is precisely considered, and transfer can be successfully achieved for all the DPs. In addition, strand witness samples were simultaneously heat treated with the DPs, and their critical current (Ic) was measured. Subsequently, it was confirmed that the average Ic is equivalent to those in the strand acceptance test while the standard deviation of Ic for the witness samples is approximately 4 % larger than that for the strand acceptance test. It was also confirmed that the disturbance of the heat treatment was negligible. Related results are described herein. |
|||||
書誌情報 |
IEEE Transactions on Applied Superconductivity 巻 32, 号 6, 発行日 2022-02 |
|||||
出版者 | ||||||
出版者 | IEEE | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1051-8223 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/TASC.2022.3147728 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9699020 |