{"created":"2023-05-15T15:02:42.074187+00:00","id":85011,"links":{},"metadata":{"_buckets":{"deposit":"aab64328-c224-408b-a991-13579b2d9e24"},"_deposit":{"created_by":1,"id":"85011","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"85011"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00085011","sets":["1"]},"author_link":["1042942","1042945","1042950","1042943","1042944","1042947","1042956","1042954","1042948","1042953","1042949","1042952","1042955","1042951","1042941","1042946"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2022-02","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"6","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Applied Superconductivity"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"In Japan, 9 ITER TF coils were manufactured for the ITER project. Each TF coil consists of seven Nb3Sn conductor double pancakes (DPs). In DP manufacturing, heat treatment is one of the most important processes, because the insertion of a heat treated conductor into the radial plate groove (i.e., transfer) is complicated owing to the elongation of the conductor under heat treatment. A critical current distribution over the DP may also occur owing to the temperature distribution and disturbance in the heat treatment process. \nTo address these issues, this study developed a procedure wherein the conductor length elongation caused by heat treatment is precisely considered, and transfer can be successfully achieved for all the DPs. In addition, strand witness samples were simultaneously heat treated with the DPs, and their critical current (Ic) was measured. Subsequently, it was confirmed that the average Ic is equivalent to those in the strand acceptance test while the standard deviation of Ic for the witness samples is approximately 4 % larger than that for the strand acceptance test. It was also confirmed that the \ndisturbance of the heat treatment was negligible. Related results are described herein.","subitem_description_type":"Abstract"}]},"item_8_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"IEEE"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/TASC.2022.3147728","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=9699020","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1051-8223","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Hideki, Kajitani"}],"nameIdentifiers":[{"nameIdentifier":"1042941","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mio, Nakamoto"}],"nameIdentifiers":[{"nameIdentifier":"1042942","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshizawa, Kazumi"}],"nameIdentifiers":[{"nameIdentifier":"1042943","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuhiro, Uno"}],"nameIdentifiers":[{"nameIdentifier":"1042944","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsutomu, Kawasaki"}],"nameIdentifiers":[{"nameIdentifier":"1042945","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kunihiro, Matsui"}],"nameIdentifiers":[{"nameIdentifier":"1042946","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Norikiyo, Koizumi"}],"nameIdentifiers":[{"nameIdentifier":"1042947","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masataka, Nakahira"}],"nameIdentifiers":[{"nameIdentifier":"1042948","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hideki, Kajitani","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042949","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Mio, Nakamoto","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042950","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yoshizawa, Kazumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042951","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Yasuhiro, Uno","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042952","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Tsutomu, Kawasaki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042953","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kunihiro, Matsui","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042954","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Norikiyo, Koizumi","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042955","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Masataka, Nakahira","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"1042956","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Results of ITER TF coil double pancake heat treatment in Japan ","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Results of ITER TF coil double pancake heat treatment in Japan "}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-02-07"},"publish_date":"2022-02-07","publish_status":"0","recid":"85011","relation_version_is_last":true,"title":["Results of ITER TF coil double pancake heat treatment in Japan "],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T17:20:50.944497+00:00"}