WEKO3
アイテム
Determination of three antiepileptic drugs in pharmaceutical formulations using microfluidic chips coupled with light-emitting diode induced fluorescence detection
https://repo.qst.go.jp/records/83841
https://repo.qst.go.jp/records/838414d593aca-6358-4704-9e6d-0d625bf433bd
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2021-09-29 | |||||
| タイトル | ||||||
| タイトル | Determination of three antiepileptic drugs in pharmaceutical formulations using microfluidic chips coupled with light-emitting diode induced fluorescence detection | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
M.Zeid, Abdallah
× M.Zeid, Abdallah× Jeehan M. Nasr, Jenny× Belal, Fathalla× I. Walash, Mohamed× Yoshinobu, Baba× Kaji, Noritada× Yoshinobu, Baba |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | In this study, a facile, sensitive, and precise lab-on-a-chip electrophoretic method coupled with light-emitting diode induced fluorescence (LED-IF) detection was developed to assay three antiepileptic drugs, namely, vigabatrin, pregabalin, and gabapentin, in pharmaceutical formulations. The analytes were derivatised offline for the first time with fluorescine-5-isothiocyanate (FITC) to yield highly fluorescent derivatives with λex/em of 490/520 nm. The FITC-labelled analytes were injected, separated, and quantitated by a microfluidic electrophoresis device using fluorescence detection. The labelled analytes were monitored using a blue LED-IF system. The separation conditions were significantly optimised adding specific concentrations of heptakis-(2,6-di-O-methyl)-β-cyclodextrin (HDM-β-CD) and methylcellulose to the buffer solution (40 mM borate buffer). HDM-β-CD acted as a selective host for the studied antiepileptic drugs, rendering a high separation efficiency. Methylcellulose was used as an efficient dynamic coating polymer to prevent the labelled drugs from being adsorbed on the inner surfaces of the poly (methylmethacrylate) microchannels. A laboratory-prepared ternary mixture of the three antiepileptic drugs was separated within 100 s with acceptable resolution between all the three analytes (Rs > 3) and a high number of theoretical plates (N) for each analyte (N ≈ 106 plates/m). The sensitivity of the method was enhanced approximately 80-fold by stacking to yield a detection limit below 0.6 ng mL−1 in the concentration range of 2.0–200.0 ng mL−1. The method was successfully validated for analysing the studied drugs in their pharmaceutical formulations. | |||||
| 書誌情報 |
Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy 巻 246, 号 5, p. 119021, 発行日 2021-02 |
|||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 1386-1425 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.saa.2020.119021 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.sciencedirect.com/science/article/abs/pii/S1386142520310003?via%3Dihub#! | |||||