Optimization of GFAG Crystal Surface Treatment for SiPM Based Clinical TOF PET Detector

https://repo.qst.go.jp/records/83621
https://repo.qst.go.jp/records/83621
833454fe-16c7-481f-8dfc-0233cac4797c
Item type 会議発表用資料 / Presentation(1)
公開日 2021-10-15
タイトル
タイトル Optimization of GFAG Crystal Surface Treatment for SiPM Based Clinical TOF PET Detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kang, Hangyu

× Kang, Hangyu

WEKO 1007721

Kang, Hangyu

Search repository
Kang, Hangyu

× Kang, Hangyu

WEKO 1007722

en Kang, Hangyu

Search repository
抄録
内容記述タイプ Abstract
内容記述 Coincidence timing resolution (CTR) is one of the important parameters in state-of-the-art clinical positron emission tomography (PET) scanners to increase the signal-to-noise ratio of reconstructed PET images by using time-of-flight (TOF) information. The aim of this study was to enhance the CTR and energy resolution of a silicon photomultiplier (SiPM) based clinical TOF-PET detector by optimizing the crystal surface treatment used for a 20 mm long crystal geometry. The TOF-PET detector consisted of a cerium doped gadolinium fine aluminum gallate (Ce:GFAG) scintillation crystal (3.0 × 3.0 × 20 mm3, C&A, Japan) and an SiPM (Hamamatsu, S13360-3050CS, Japan) with an effective area of 3.0 × 3.0 mm2. s with Eight different types of GFAG crystal surface treatment: mechanical polishing (M.P) of all surfaces and seven different partial saw-cuts (i.e. top, ⅟₂-side lower, ½-side upper, 1-side, 2-side, 3-side, and 4-side) were used to find the optimal treatment. The timing and energy signals were extracted by using a high-frequency SiPM readout circuit and then were digitized by using a CAMAC DAQ system. The 1-side saw-cut resulted in a 14 ps better CTR (203±3 ps) and 1.9% better energy resolution (9.3%) over those of the M.P crystal (CTR=217±4 ps, energy resolution=11.2%). The ⅟₂-side saw-cut enhanced the CTR (203±3 ps), however the energy resolution (12.5%) was degraded due to the variation in light collection efficiency along the crystal depth. In conclusion, the 1-side saw-cut was the optimal crystal surface treatment in terms of CTR and energy resolution for the SiPM based TOF PET detector.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 2021 Virtual IEEE Nuclear Science Symposium and Medical Imaging Conference
発表年月日
日付 2021-10-22
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:24:22.005687
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3