Monte Carlo simulation of the acquisition conditions for 177Lu molecular imaging of hepatic tumors.
https://repo.qst.go.jp/records/82943
https://repo.qst.go.jp/records/829436a08b85f-3854-4682-9dda-82ccd62e6d12
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2021-06-04 | |||||
タイトル | ||||||
タイトル | Monte Carlo simulation of the acquisition conditions for 177Lu molecular imaging of hepatic tumors. | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Yuya, Sekikawa
× Yuya, Sekikawa× Keita, Funada× Go, Akamatsu× Kazuhiko, Himuro× Akihiko, Takahashi× Shingo, Baba× Masayuki, Sasaki× Go, Akamatsu |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Objective: To examine the impact of acquisition time on Lutetium-177 (177Lu) single-photon emission computed tomography (SPECT) images using Monte Carlo simulation. Methods: A gamma camera simulation based on the Monte Carlo method was performed to produce SPECT images. The phantom was modeled on a NEMA IEC BODY phantom including six spheres as tumors. After the administration of 7.4 GBq of 177Lu, radioactivity concentrations of the tumor/liver at 6, 24, and 72 h after administration were set to 1.85/0.201, 2.12/0.156, and 1.95/0.117 MBq/mL, respectively. In addition, the radioactivity concentrations of the tumor at 72 h after administration varied by 1/2, 1/4, and 1/8 when comparison was made. Acquisition times examined were 1.2, 1.5, 2, 3, 6, and 12 min. To assess the impact of collimators, SPECT data acquired at 72 h after the administration using six collimators of low-energy high-resolution (LEHR), extended low-energy general-purpose (ELEGP), medium-energy, and general-purpose (MEGP-1, MEGP-2, and MEGP-3) and high-energy general-purpose (HEGP) were examined. After prefiltering using a Butterworth filter, projection images were reconstructed using ordered subset expectation maximization. The detected photons were classified into direct rays, scattered rays, penetrating rays, and characteristic X-rays from lead. The image quality was evaluated through visual assessment, and physical assessment of contrast recovery coefficient (CRC) and contrast-to-noise ratio (CNR). In this study, the CNR threshold for detectability was assumed to be 5.0. Results: To compare collimators, the highest sensitivity was observed with ELEGP, followed by LEHR and MEGP-1. The highest ratio of direct ray was also observed in ELEGP followed by MEGP-1. In comparison of the radioactivity concentration ratios of tumor/liver, CRC and CNR were significantly decreased with smaller radioactivity concentration ratios. This effect was greater with larger spheres. According to the visual assessment, the acquisition time of 6, 6, and 3 min or longer was required using ELEGP collimator at 6, 24, and 72 h after administration, respectively. Physical assessment based on CNR and CRC also suggested that 6, 6, and 3 min or longer acquisition time was necessary at 6, 24, and 72 h after administration. Conclusion: 177Lu-SPECT images generated via the Monte Carlo simulation suggested that the recommended acquisition time was 6 min or longer at 6 and 24 h and 3 min or longer at 72 h after administration. |
|||||
書誌情報 |
Annals of Nuclear Medicine 巻 35, p. 823-833, 発行日 2021-05 |
|||||
出版者 | ||||||
出版者 | Springer Nature | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0914-7187 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 34057655 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s12149-021-01620-9 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007%2Fs12149-021-01620-9 |