WEKO3
アイテム
Three-Dimensional Nondestructive Isotope-Selective Tomographic Imaging of 208Pb Distribution via Nuclear Resonance Fluorescence
https://repo.qst.go.jp/records/82715
https://repo.qst.go.jp/records/827154f3ab61b-3a7b-4ba8-ab56-e3fa4f573bbf
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2021-04-12 | |||||
| タイトル | ||||||
| タイトル | Three-Dimensional Nondestructive Isotope-Selective Tomographic Imaging of 208Pb Distribution via Nuclear Resonance Fluorescence | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Ali, Khaled
× Ali, Khaled× Zen, Heishun× Ohgaki, Hideaki× Kii, Toshiteru× Hayakawa, Takehito× Toshiyuki, Shizuma× Toyokawa, Hiroyuki× Fujimoto, Masaki× Taira, Yoshitaka× Katoh, Masahiro× Takehito, Hayakawa× Toshiyuki, Shizuma |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Combining the nuclear resonance fluorescence (NRF) transmission method with computed tomography (CT) can be a novel method for imaging the isotope distributions, which is indispensable in nuclear engineering. We performed an experiment to reconstruct a three-dimensional NRF-CT image with isotope selectivity of enriched lead isotope rods (208Pb) together with a set of different rods, including another enriched isotope (206Pb), iron, and aluminum rods, inserted into a cylindrical aluminum holder. Using a laser Compton scattering (LCS) gamma ray beam with a 5.528 MeV maximum energy, 2 mm beam size, and 10 photon·s−1·eV−1 flux density, which is available at the BL1U beamline in the ultraviolet synchrotron orbital radiation-III (UVSOR-III) synchrotron radiation facility at the Institute of Molecular Science at the National Institutes of Natural Sciences in Japan, and we excited the Jπ = 1− NRF level at 5.512 MeV in 208Pb. An isotope-selective three-dimensional NRF-CT image of the 208Pb isotope distribution was experimentally obtained for the first time with a pixel resolution of 4 mm in the horizontal plane. |
|||||
| 書誌情報 |
Applied sciences 巻 11, 号 8, p. 3415, 発行日 2021-04 |
|||||
| 出版者 | ||||||
| 出版者 | MDPI | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 2076-3417 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.3390/app11083415 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.mdpi.com/2076-3417/11/8/3415 | |||||