ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Assessment of semi-quantitative evaluation using SUV applying 2 phase-imaging of IMP SPECT for diagnosis of choroidal melanoma

https://repo.qst.go.jp/records/81857
https://repo.qst.go.jp/records/81857
7948f6a7-0c7f-4939-aa34-f2545227cb58
Item type 会議発表用資料 / Presentation(1)
公開日 2021-02-17
タイトル
タイトル Assessment of semi-quantitative evaluation using SUV applying 2 phase-imaging of IMP SPECT for diagnosis of choroidal melanoma
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kana, Yamazaki

× Kana, Yamazaki

WEKO 926789

Kana, Yamazaki

Search repository
Ryuichi, Nishii

× Ryuichi, Nishii

WEKO 926790

Ryuichi, Nishii

Search repository
Tatsuya, Higashi

× Tatsuya, Higashi

WEKO 926791

Tatsuya, Higashi

Search repository
Hirokazu, Makishima

× Hirokazu, Makishima

WEKO 926792

Hirokazu, Makishima

Search repository
Goro, Kasuya

× Goro, Kasuya

WEKO 926793

Goro, Kasuya

Search repository
Chang, Tachen

× Chang, Tachen

WEKO 926794

Chang, Tachen

Search repository
Koji, Murakami

× Koji, Murakami

WEKO 926795

Koji, Murakami

Search repository
Kentaro, Tamura

× Kentaro, Tamura

WEKO 926796

Kentaro, Tamura

Search repository
Hiroshi, Tsuji

× Hiroshi, Tsuji

WEKO 926797

Hiroshi, Tsuji

Search repository
Kana, Yamazaki

× Kana, Yamazaki

WEKO 926798

en Kana, Yamazaki

Search repository
Ryuichi, Nishii

× Ryuichi, Nishii

WEKO 926799

en Ryuichi, Nishii

Search repository
Tatsuya, Higashi

× Tatsuya, Higashi

WEKO 926800

en Tatsuya, Higashi

Search repository
Hirokazu, Makishima

× Hirokazu, Makishima

WEKO 926801

en Hirokazu, Makishima

Search repository
Goro, Kasuya

× Goro, Kasuya

WEKO 926802

en Goro, Kasuya

Search repository
Chang, Tachen

× Chang, Tachen

WEKO 926803

en Chang, Tachen

Search repository
Koji, Murakami

× Koji, Murakami

WEKO 926804

en Koji, Murakami

Search repository
Kentaro, Tamura

× Kentaro, Tamura

WEKO 926805

en Kentaro, Tamura

Search repository
Hiroshi, Tsuji

× Hiroshi, Tsuji

WEKO 926806

en Hiroshi, Tsuji

Search repository
抄録
内容記述タイプ Abstract
内容記述 [Objectives]
Choroidal melanoma is the most common primary ocular malignant tumor. I-123-IMP SPECT (IMP SPECT) was reported to be a useful diagnostic imaging tool for choroidal melanoma. However, evaluation by SPECT is qualitative with inadequate anatomical information, and there are some issues to be left for the accuracy of its methodology. The purpose of this study was to assess the diagnostic ability of IMP SPECT and to assess semi-quantitative evaluation applying SUV in patients with choroidal melanoma. We also examined the association between SUV and uptake index (UI) which was a conventional method.
[Methods]
Twelve patients (5 males, 7 females) underwent IMP SPECT as an assessment before carbon-ion radiotherapy for choroidal melanoma. The mean age of patients is 62.4 ± 9.63 (ranged from 42 to 76) years old. SPECT imaging was performed using a gamma camera 6 and 24 hours after intravenous injection of 215.3 ± 8.4 MBq of 123I-IMP as the 2 phase-imaging.
For data analysis by SUVmax, 6- and 24-hours SPECT images were fused with CT images using an image-analysis software. The volume of interests (VOIs) of the whole eyeballs on the tumor side and the contralateral normal side were drawn, followed by semi-quantitative evaluations by SUVmax. Uptake index (UI) by radioisotope counts on SPECT images, which is a conventional method, was also examined to compare with the diagnostic ability of SUVmax.
[Results]
Six hours after intravenous injection, SUVmax of tumor side was 2.37 ± 0.88, normal side was 1.77 ± 0.39, significantly higher on the tumor side (P <0.05). After 24 hours, SUVmax of tumor side was 3.25 ± 1.57, normal side was 1.87 ± 0.22, significantly higher on the tumor side (P <0.01). There was a high correlation between SUVmax after 6 hours and 24 hours on the tumor side (ρ = 0.84, P <0.001). Six hours after intravenous injection, the UI of tumor side was 2.24 ± 0.67, normal side was 1.53 ± 0.35, significantly higher on the tumor side (P <0.05). After 24 hours, the UI of tumor side was 4.03 ± 1.30, normal side was 1.95 ± 0.46, significantly higher on the tumor side (P <0.01). There was no significant correlation between tumor-UI and tumor side SUVmax after 6 hours (ρ = 0.47, P =0.124), whereas high correlation between those of after 24 hours (ρ = 0.87, P <0.001).
[Conclusions]
Semi-quantitative evaluation using SUV had an association with conventional UI. And 2 phase-imaging of IMP SPECT was promising and useful for the diagnosis of choroidal melanoma.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 SNMMI 2020 Annual Meeting - Virtual Edition
発表年月日
日付 2020-07-11
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:48:50.963847
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3