ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Clinical value of PET/CT with carbon-11 4DST in the evaluation of malignant and benign lung tumors

https://repo.qst.go.jp/records/81842
https://repo.qst.go.jp/records/81842
1b30ee4c-78b3-47ae-86e4-6ed1a897dde7
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-12-04
タイトル
タイトル Clinical value of PET/CT with carbon-11 4DST in the evaluation of malignant and benign lung tumors
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishii, Ryuichi

× Nishii, Ryuichi

WEKO 1012382

Nishii, Ryuichi

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 1012383

Saga, Tsuneo

Search repository
Sudo, Hitomi

× Sudo, Hitomi

WEKO 1012384

Sudo, Hitomi

Search repository
Togawa, Takashi

× Togawa, Takashi

WEKO 1012385

Togawa, Takashi

Search repository
Kuyama, Junpei

× Kuyama, Junpei

WEKO 1012386

Kuyama, Junpei

Search repository
Tani, Toshiaki

× Tani, Toshiaki

WEKO 1012387

Tani, Toshiaki

Search repository
Maeda, Takamasa

× Maeda, Takamasa

WEKO 1012388

Maeda, Takamasa

Search repository
Kobayashi, Masato

× Kobayashi, Masato

WEKO 1012389

Kobayashi, Masato

Search repository
Iizasa, Toshihiko

× Iizasa, Toshihiko

WEKO 1012390

Iizasa, Toshihiko

Search repository
Shingyoji, Masato

× Shingyoji, Masato

WEKO 1012391

Shingyoji, Masato

Search repository
Itami, Makiko

× Itami, Makiko

WEKO 1012392

Itami, Makiko

Search repository
Kawamura, Kazunori

× Kawamura, Kazunori

WEKO 1012393

Kawamura, Kazunori

Search repository
Hashimoto, Hiroki

× Hashimoto, Hiroki

WEKO 1012394

Hashimoto, Hiroki

Search repository
Yamazaki, Kana

× Yamazaki, Kana

WEKO 1012395

Yamazaki, Kana

Search repository
Tamura, Kentaro

× Tamura, Kentaro

WEKO 1012396

Tamura, Kentaro

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 1012397

Higashi, Tatsuya

Search repository
Ryuichi, Nishii

× Ryuichi, Nishii

WEKO 1012398

en Ryuichi, Nishii

Search repository
Tsuneo, Saga

× Tsuneo, Saga

WEKO 1012399

en Tsuneo, Saga

Search repository
Hitomi, Sudo

× Hitomi, Sudo

WEKO 1012400

en Hitomi, Sudo

Search repository
Toshiaki, Tani

× Toshiaki, Tani

WEKO 1012401

en Toshiaki, Tani

Search repository
Takamasa, Maeda

× Takamasa, Maeda

WEKO 1012402

en Takamasa, Maeda

Search repository
Kana, Yamazaki

× Kana, Yamazaki

WEKO 1012403

en Kana, Yamazaki

Search repository
Kentaro, Tamura

× Kentaro, Tamura

WEKO 1012404

en Kentaro, Tamura

Search repository
Tatsuya, Higashi

× Tatsuya, Higashi

WEKO 1012405

en Tatsuya, Higashi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objectives: The aim of this study was to assess the clinical value of [11C]4DST uptake in patients with lung nodules, including benign and malignant tumors, and to assess the correlation between [11C]4DST uptake and proliferative activity of tumors in comparison with [18F]FDG uptake.
Methods: Twenty-six patients (22 males and 4 females, mean age of 65.5-year-old) were analyzed in this prospective study. Patients underwent [11C]4DST and [18F]FDG PET/CT imaging on the same day. Diagnosis of each lung nodule was confirmed by histopathological examination of tissue specimens at surgery, or during clinical follow-up after the PET/CT studies. To assess the utility of the semi-quantitative evaluation method, the SUVmax was calculated of [11C]4DST and [18F]FDG uptake by the lesion. Proliferative activities of each tumor as indicated by the immunohistochemical Ki-67 index was also estimated using surgical specimens of patients. Then the relationship between the SUVmax of both PET/CT and the Ki-67 index was examined. Furthermore, the relationship between the uptake of [11C]4DST or [18F]FDG and the histopathological findings, the clinical stage, and the clinical outcome of patients were also assessed.
Results: There was a positive linear relationship between the SUVmax of [11C]4DST images and the Ki-67 index (Correlation coefficients = 0.68). The SUVmax of [11C]4DST in the 26 lung nodules were 1.65 ± 0.40 for benign lesions, 3.09 ± 0.83 for adenocarcinomas (P < 0.001 between benign and adenocarcinoma), and 2.92 ± 0.58 for SqCCs (P < 0.001 between benign and SqCC). Whereas, the SUVmax of [18F]FDG were 2.38 ± 2.27 for benign lesions, 6.63 ± 4.24 for adenocarcinomas (n.s.), and 7.52 ± 2.84 for SqCCs (n.s.). The relationship between TNM tumor stage and the SUVmax of [11C]4DST were 2.54 ± 0.37 for T1, 3.48 ± 0.57 for T2, and 4.17 ± 0.72 for T3 (P < 0.005 between T1 and T2, and P < 0.001 between T1 and T3). In comparison with the TNM pathological stage, SUVmax of [11C]4DST were 2.63 ± 0.49 for stage I, 3.36 ± 0.23 for stage II, 3.40 ± 1.12 for stage III, and 4.65 for stage IV (P < 0.05 between stages I and II). In comparison of the clinical outcome, the SUVmax of [11C]4DST were 2.72 ± 0.56 for the no recurrence (No Rec.) group, 3.10 ± 0.33 for the recurrence-free with adjuvant chemotherapy after the surgery (the No Rec. Adjv. CTx. group) and 4.66 ± 0.02 for the recurrence group (Rec. group) (P < 0.001 between the No Rec and Rec. groups, and P < 0.005 between the No Rec. Adjv. CTx. and Rec. groups).
Conclusions: PET/CT with [11C]4DST is as feasible for imaging of lung tumors as [18F]FDG PET/CT. For diagnosing lung tumors, [11C]4DST PET is useful in distinguishing benign nodules from malignancies. [11C]4DST uptake in lung carcinomas is correlated with the proliferative activity of tumors, indicating a promising noninvasive PET imaging of DNA synthesis in malignant lung tumors.
書誌情報 Annals of nuclear medicine

巻 35, p. 211-222, 発行日 2021-01
出版者
出版者 Springer Japan
ISSN
収録物識別子タイプ ISSN
収録物識別子 0914-7187
PubMed番号
識別子タイプ PMID
関連識別子 33387282
DOI
識別子タイプ DOI
関連識別子 10.1007/s12149-020-01554-8
関連サイト
識別子タイプ URI
関連識別子 https://link.springer.com/article/10.1007/s12149-020-01554-8
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:19:15.657751
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3