ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Carbon ion radiotherapy for sacral chordoma: A retrospective nationwide multicentre study in Japan

https://repo.qst.go.jp/records/81785
https://repo.qst.go.jp/records/81785
7f817c20-12ed-48eb-b931-710456e247c0
Item type 学術雑誌論文 / Journal Article(1)
公開日 2021-02-05
タイトル
タイトル Carbon ion radiotherapy for sacral chordoma: A retrospective nationwide multicentre study in Japan
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Demizu, Yusuke

× Demizu, Yusuke

WEKO 1006156

Demizu, Yusuke

Search repository
Reiko, Imai

× Reiko, Imai

WEKO 1006157

Reiko, Imai

Search repository
Hiroki, Kiyohara

× Hiroki, Kiyohara

WEKO 1006158

Hiroki, Kiyohara

Search repository
Akira, Matsunobu

× Akira, Matsunobu

WEKO 1006159

Akira, Matsunobu

Search repository
Masahiko, Okamoto

× Masahiko, Okamoto

WEKO 1006160

Masahiko, Okamoto

Search repository
Tomoaki, Okimoto

× Tomoaki, Okimoto

WEKO 1006161

Tomoaki, Okimoto

Search repository
Hiroshi, Tsuji

× Hiroshi, Tsuji

WEKO 1006162

Hiroshi, Tsuji

Search repository
Tatsuya, Ohno

× Tatsuya, Ohno

WEKO 1006163

Tatsuya, Ohno

Search repository
Yoshiyuki, Shioyama

× Yoshiyuki, Shioyama

WEKO 1006164

Yoshiyuki, Shioyama

Search repository
Kenji, Nemoto

× Kenji, Nemoto

WEKO 1006165

Kenji, Nemoto

Search repository
Takashi, Nakano

× Takashi, Nakano

WEKO 1006166

Takashi, Nakano

Search repository
Tadashi, Kamada

× Tadashi, Kamada

WEKO 1006167

Tadashi, Kamada

Search repository
Reiko, Imai

× Reiko, Imai

WEKO 1006168

en Reiko, Imai

Search repository
Hiroki, Kiyohara

× Hiroki, Kiyohara

WEKO 1006169

en Hiroki, Kiyohara

Search repository
Akira, Matsunobu

× Akira, Matsunobu

WEKO 1006170

en Akira, Matsunobu

Search repository
Masahiko, Okamoto

× Masahiko, Okamoto

WEKO 1006171

en Masahiko, Okamoto

Search repository
Tomoaki, Okimoto

× Tomoaki, Okimoto

WEKO 1006172

en Tomoaki, Okimoto

Search repository
Hiroshi, Tsuji

× Hiroshi, Tsuji

WEKO 1006173

en Hiroshi, Tsuji

Search repository
Tatsuya, Ohno

× Tatsuya, Ohno

WEKO 1006174

en Tatsuya, Ohno

Search repository
Yoshiyuki, Shioyama

× Yoshiyuki, Shioyama

WEKO 1006175

en Yoshiyuki, Shioyama

Search repository
Kenji, Nemoto

× Kenji, Nemoto

WEKO 1006176

en Kenji, Nemoto

Search repository
Takashi, Nakano

× Takashi, Nakano

WEKO 1006177

en Takashi, Nakano

Search repository
Tadashi, Kamada

× Tadashi, Kamada

WEKO 1006178

en Tadashi, Kamada

Search repository
抄録
内容記述タイプ Abstract
内容記述 Background and purpose: Usefulness of carbon ion radiotherapy (CIRT) for sacral chordoma has been reported from single institutions. We conducted a retrospective nationwide multicentre study to evaluate the clinical outcomes of CIRT for sacral chordoma in Japan.
Materials and methods: A total of 219 patients who underwent CIRT for sacral chordoma at institutions across Japan between December 2003 and July 2014 were included in this study.
Results: Median patient age was 67 years (range, 26-87 years). Most patients had no history of surgical resection (96%). The most frequent planning target volume (PTV) range was 100-500 mL (65%). The most frequently used dose-fractionation was 67.2 Gy (relative biological effectiveness) in 16 fractions (65%). The median follow-up was 56 months (range, 7-132 months). The 5-year overall survival (OS), progression-free survival, and local control rates were 84%, 48%, and 72%, respectively. Frequent sites of out-of-field recurrence included bone (9%) and lung (9%) metastases. The Cox proportional hazards model revealed that both younger age (P = 0.004) and smaller PTV (P = 0.001) were associated with significantly better OS. Acute toxicities of ≥Grade 3 occurred in eight patients (4%). Late toxicities of ≥Grade 3 occurred in 13 patients (6%): skin disorders in six patients (3%), pain in three (1%), myositis in three (1%), etc. CONCLUSION: Our retrospective nationwide multicentre study showed that CIRT for sacral chordoma was effective and safe, and replicated the previously reported data from a representative CIRT institution in Japan demonstrating high local control and low toxicity rates.
書誌情報 Radiotherapy and oncology

巻 154, p. 1-5, 発行日 2020-09
出版者
出版者 Elsevier
ISSN
収録物識別子タイプ ISSN
収録物識別子 0167-8140
PubMed番号
識別子タイプ PMID
関連識別子 32941958
DOI
識別子タイプ DOI
関連識別子 10.1016/j.radonc.2020.09.018
関連サイト
識別子タイプ DOI
関連識別子 https://doi.org/10.1016/j.radonc.2020.09.018
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:26:05.329559
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3