ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method

https://repo.qst.go.jp/records/80487
https://repo.qst.go.jp/records/80487
844ffca0-fdf2-4d6f-bd68-0dcf3917c0d6
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-09-09
タイトル
タイトル Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ali, Khaled

× Ali, Khaled

WEKO 888826

Ali, Khaled

Search repository
Ohgaki, Hideaki

× Ohgaki, Hideaki

WEKO 888827

Ohgaki, Hideaki

Search repository
Zen, Heishun

× Zen, Heishun

WEKO 888828

Zen, Heishun

Search repository
Kii, Toshiteru

× Kii, Toshiteru

WEKO 888829

Kii, Toshiteru

Search repository
Hayakawa, Takehito

× Hayakawa, Takehito

WEKO 888830

Hayakawa, Takehito

Search repository
Shizuma, Toshiyuki

× Shizuma, Toshiyuki

WEKO 888831

Shizuma, Toshiyuki

Search repository
Toyokawa, Hiroyuki

× Toyokawa, Hiroyuki

WEKO 888832

Toyokawa, Hiroyuki

Search repository
Taira, Yoshitaka

× Taira, Yoshitaka

WEKO 888833

Taira, Yoshitaka

Search repository
Iancu, Violeta

× Iancu, Violeta

WEKO 888834

Iancu, Violeta

Search repository
Turturica, Gabriel

× Turturica, Gabriel

WEKO 888835

Turturica, Gabriel

Search repository
C˘alin, Alexandru Ur

× C˘alin, Alexandru Ur

WEKO 888836

C˘alin, Alexandru Ur

Search repository
Fujimoto, Masaki

× Fujimoto, Masaki

WEKO 888837

Fujimoto, Masaki

Search repository
Katoh, Masahiro

× Katoh, Masahiro

WEKO 888838

Katoh, Masahiro

Search repository
Hayakawa, Takehito

× Hayakawa, Takehito

WEKO 888839

en Hayakawa, Takehito

Search repository
Shizuma, Toshiyuki

× Shizuma, Toshiyuki

WEKO 888840

en Shizuma, Toshiyuki

Search repository
抄録
内容記述タイプ Abstract
内容記述 The isotope selectivity of the Computed Tomography (CT) imaging based on the Nuclear Resonance Fluorescence (NRF) absorption method using a quasi-monochromatic Laser Compton Scattering (LCS) gamma-ray beam in MeV region was demonstrated at the UVSOR-III synchrotron radiation facility with a sample target including two enriched lead isotope rods made of 206Pb and 208Pb. A CT image of 208Pb in the sample target was selectively obtained using an excited state with Jπ=1- at 5.512 MeV in 208Pb. The intensity of the LCS gamma-ray beam was greater than 1×10^8 photons/s without a collimating. A lead collimator with a hole diameter of 1 mm was used. Two-dimensional NRF-CT image of 208Pb isotope distribution was clearly obtained with a 2 mm pixel size resolution which was determined by the horizontal step size of the CT stage.
書誌情報 IEEE Transactions on Nuclear Science

巻 67, p. 1976-1984, 発行日 2020-09
ISSN
収録物識別子タイプ ISSN
収録物識別子 0018-9499
DOI
識別子タイプ DOI
関連識別子 10.1109/tns.2020.3004565
関連サイト
識別子タイプ URI
関連識別子 https://ieeexplore.ieee.org/document/9059859
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:01:13.207269
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3