WEKO3
アイテム
{"_buckets": {"deposit": "ec051087-05fa-471c-b15a-bdeb344796a5"}, "_deposit": {"created_by": 1, "id": "80487", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "80487"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00080487", "sets": ["1"]}, "author_link": ["888826", "888828", "888831", "888830", "888827", "888833", "888839", "888832", "888840", "888834", "888829", "888836", "888838", "888835", "888837"], "item_8_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2020-09", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "1984", "bibliographicPageStart": "1976", "bibliographicVolumeNumber": "67", "bibliographic_titles": [{"bibliographic_title": "IEEE Transactions on Nuclear Science"}]}]}, "item_8_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The isotope selectivity of the Computed Tomography (CT) imaging based on the Nuclear Resonance Fluorescence (NRF) absorption method using a quasi-monochromatic Laser Compton Scattering (LCS) gamma-ray beam in MeV region was demonstrated at the UVSOR-III synchrotron radiation facility with a sample target including two enriched lead isotope rods made of 206Pb and 208Pb. A CT image of 208Pb in the sample target was selectively obtained using an excited state with Jπ=1- at 5.512 MeV in 208Pb. The intensity of the LCS gamma-ray beam was greater than 1×10^8 photons/s without a collimating. A lead collimator with a hole diameter of 1 mm was used. Two-dimensional NRF-CT image of 208Pb isotope distribution was clearly obtained with a 2 mm pixel size resolution which was determined by the horizontal step size of the CT stage.", "subitem_description_type": "Abstract"}]}, "item_8_relation_14": {"attribute_name": "DOI", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "10.1109/tns.2020.3004565", "subitem_relation_type_select": "DOI"}}]}, "item_8_relation_17": {"attribute_name": "関連サイト", "attribute_value_mlt": [{"subitem_relation_type_id": {"subitem_relation_type_id_text": "https://ieeexplore.ieee.org/document/9059859", "subitem_relation_type_select": "URI"}}]}, "item_8_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0018-9499", "subitem_source_identifier_type": "ISSN"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Ali, Khaled"}], "nameIdentifiers": [{"nameIdentifier": "888826", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ohgaki, Hideaki"}], "nameIdentifiers": [{"nameIdentifier": "888827", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zen, Heishun"}], "nameIdentifiers": [{"nameIdentifier": "888828", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kii, Toshiteru"}], "nameIdentifiers": [{"nameIdentifier": "888829", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayakawa, Takehito"}], "nameIdentifiers": [{"nameIdentifier": "888830", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shizuma, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "888831", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Toyokawa, Hiroyuki"}], "nameIdentifiers": [{"nameIdentifier": "888832", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Taira, Yoshitaka"}], "nameIdentifiers": [{"nameIdentifier": "888833", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iancu, Violeta"}], "nameIdentifiers": [{"nameIdentifier": "888834", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Turturica, Gabriel"}], "nameIdentifiers": [{"nameIdentifier": "888835", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "C˘alin, Alexandru Ur"}], "nameIdentifiers": [{"nameIdentifier": "888836", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Fujimoto, Masaki"}], "nameIdentifiers": [{"nameIdentifier": "888837", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Katoh, Masahiro"}], "nameIdentifiers": [{"nameIdentifier": "888838", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Hayakawa, Takehito", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "888839", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shizuma, Toshiyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "888840", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method"}]}, "item_type_id": "8", "owner": "1", "path": ["1"], "permalink_uri": "https://repo.qst.go.jp/records/80487", "pubdate": {"attribute_name": "公開日", "attribute_value": "2020-09-09"}, "publish_date": "2020-09-09", "publish_status": "0", "recid": "80487", "relation": {}, "relation_version_is_last": true, "title": ["Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method"], "weko_shared_id": -1}
Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method
https://repo.qst.go.jp/records/80487
https://repo.qst.go.jp/records/80487844ffca0-fdf2-4d6f-bd68-0dcf3917c0d6
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-09-09 | |||||
タイトル | ||||||
タイトル | Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Ali, Khaled
× Ali, Khaled× Ohgaki, Hideaki× Zen, Heishun× Kii, Toshiteru× Hayakawa, Takehito× Shizuma, Toshiyuki× Toyokawa, Hiroyuki× Taira, Yoshitaka× Iancu, Violeta× Turturica, Gabriel× C˘alin, Alexandru Ur× Fujimoto, Masaki× Katoh, Masahiro× Hayakawa, Takehito× Shizuma, Toshiyuki |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The isotope selectivity of the Computed Tomography (CT) imaging based on the Nuclear Resonance Fluorescence (NRF) absorption method using a quasi-monochromatic Laser Compton Scattering (LCS) gamma-ray beam in MeV region was demonstrated at the UVSOR-III synchrotron radiation facility with a sample target including two enriched lead isotope rods made of 206Pb and 208Pb. A CT image of 208Pb in the sample target was selectively obtained using an excited state with Jπ=1- at 5.512 MeV in 208Pb. The intensity of the LCS gamma-ray beam was greater than 1×10^8 photons/s without a collimating. A lead collimator with a hole diameter of 1 mm was used. Two-dimensional NRF-CT image of 208Pb isotope distribution was clearly obtained with a 2 mm pixel size resolution which was determined by the horizontal step size of the CT stage. | |||||
書誌情報 |
IEEE Transactions on Nuclear Science 巻 67, p. 1976-1984, 発行日 2020-09 |
|||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0018-9499 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1109/tns.2020.3004565 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://ieeexplore.ieee.org/document/9059859 |