{"created":"2023-05-15T14:59:19.475272+00:00","id":80487,"links":{},"metadata":{"_buckets":{"deposit":"ec051087-05fa-471c-b15a-bdeb344796a5"},"_deposit":{"created_by":1,"id":"80487","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80487"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080487","sets":["1"]},"author_link":["888826","888828","888831","888830","888827","888833","888839","888832","888840","888834","888829","888836","888838","888835","888837"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-09","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"1984","bibliographicPageStart":"1976","bibliographicVolumeNumber":"67","bibliographic_titles":[{"bibliographic_title":"IEEE Transactions on Nuclear Science"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"The isotope selectivity of the Computed Tomography (CT) imaging based on the Nuclear Resonance Fluorescence (NRF) absorption method using a quasi-monochromatic Laser Compton Scattering (LCS) gamma-ray beam in MeV region was demonstrated at the UVSOR-III synchrotron radiation facility with a sample target including two enriched lead isotope rods made of 206Pb and 208Pb. A CT image of 208Pb in the sample target was selectively obtained using an excited state with Jπ=1- at 5.512 MeV in 208Pb. The intensity of the LCS gamma-ray beam was greater than 1×10^8 photons/s without a collimating. A lead collimator with a hole diameter of 1 mm was used. Two-dimensional NRF-CT image of 208Pb isotope distribution was clearly obtained with a 2 mm pixel size resolution which was determined by the horizontal step size of the CT stage.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1109/tns.2020.3004565","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://ieeexplore.ieee.org/document/9059859","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0018-9499","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Ali, Khaled"}],"nameIdentifiers":[{"nameIdentifier":"888826","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Ohgaki, Hideaki"}],"nameIdentifiers":[{"nameIdentifier":"888827","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Zen, Heishun"}],"nameIdentifiers":[{"nameIdentifier":"888828","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Kii, Toshiteru"}],"nameIdentifiers":[{"nameIdentifier":"888829","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Takehito"}],"nameIdentifiers":[{"nameIdentifier":"888830","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shizuma, Toshiyuki"}],"nameIdentifiers":[{"nameIdentifier":"888831","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Toyokawa, Hiroyuki"}],"nameIdentifiers":[{"nameIdentifier":"888832","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Taira, Yoshitaka"}],"nameIdentifiers":[{"nameIdentifier":"888833","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Iancu, Violeta"}],"nameIdentifiers":[{"nameIdentifier":"888834","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Turturica, Gabriel"}],"nameIdentifiers":[{"nameIdentifier":"888835","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"C˘alin, Alexandru Ur"}],"nameIdentifiers":[{"nameIdentifier":"888836","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Fujimoto, Masaki"}],"nameIdentifiers":[{"nameIdentifier":"888837","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Katoh, Masahiro"}],"nameIdentifiers":[{"nameIdentifier":"888838","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hayakawa, Takehito","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"888839","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Shizuma, Toshiyuki","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"888840","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-09-09"},"publish_date":"2020-09-09","publish_status":"0","recid":"80487","relation_version_is_last":true,"title":["Selective Isotope CT Imaging Based on Nuclear Resonance Fluorescence Transmission Method"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:31:30.648128+00:00"}