ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

Measurements of 73-keV X-ray time spectrum with avalanche-photodiode scintillation detector using Bi2O3-nanoparticle-doped plastic scintillator

https://repo.qst.go.jp/records/80281
https://repo.qst.go.jp/records/80281
7af5cedc-435b-45be-9cd6-2fa104432144
Item type 学術雑誌論文 / Journal Article(1)
公開日 2020-08-04
タイトル
タイトル Measurements of 73-keV X-ray time spectrum with avalanche-photodiode scintillation detector using Bi2O3-nanoparticle-doped plastic scintillator
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Kishimoto, Shunji

× Kishimoto, Shunji

WEKO 882918

Kishimoto, Shunji

Search repository
Koshimizu, Masanori

× Koshimizu, Masanori

WEKO 882919

Koshimizu, Masanori

Search repository
Hiyama, Fumiyuki

× Hiyama, Fumiyuki

WEKO 882920

Hiyama, Fumiyuki

Search repository
Haruki, Rie

× Haruki, Rie

WEKO 882921

Haruki, Rie

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 882922

Nishikido, Fumihiko

Search repository
Koshimizu, Masanori

× Koshimizu, Masanori

WEKO 882923

en Koshimizu, Masanori

Search repository
Nishikido, Fumihiko

× Nishikido, Fumihiko

WEKO 882924

en Nishikido, Fumihiko

Search repository
抄録
内容記述タイプ Abstract
内容記述 Time spectra of 73-keV X-rays were successfully observed with a scintillation detector using a Bi2O3-nanoparticle-doped plastic scintillator (PLS) and silicon avalanche photodiode (Si-APD). A 5 wt% Bi2O3-nanoparticle-doped PLS was fabricated and cut out to be mm and 0.9 mm thick, and it was mounted on a Si-APD operating in proportional mode. An organic scintillator of [2-(4-tert-butylphenyl)-5-(4-phenylphenyl)]-1,3,4-oxadiazole was used for the PLS by 1.68 mol% of polystyrene solvent. When the PLS and Si-APD were cooled to 30° C, a good time resolution of 0.35 ns (full width at half maximum) was obtained for 73.04-keV X-rays when measuring a time structure of the multibunch mode in synchrotron ring operation. The Si-APD scintillation detector mounting a Bi2O3-nanoparticle-doped PLS can be applied well to research fields that need both a high detection efficiency and a subnanosecond time resolution with a photon energy of more than 70 keV, such as synchrotron radiation nuclear resonant scattering on 193Ir.
書誌情報 Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment

巻 968, 発行日 2020-07
ISSN
収録物識別子タイプ ISSN
収録物識別子 0168-9002
DOI
識別子タイプ DOI
関連識別子 10.1016/j.nima.2020.163908
関連サイト
識別子タイプ URI
関連識別子 https://www.sciencedirect.com/science/article/pii/S0168900220303995
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:03:07.187872
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3