{"created":"2023-05-15T14:59:10.186226+00:00","id":80281,"links":{},"metadata":{"_buckets":{"deposit":"4fba0181-9451-4cae-a3e2-6ff182b4e963"},"_deposit":{"created_by":1,"id":"80281","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"80281"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00080281","sets":["1"]},"author_link":["882920","882923","882918","882924","882922","882919","882921"],"item_8_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-07","bibliographicIssueDateType":"Issued"},"bibliographicVolumeNumber":"968","bibliographic_titles":[{"bibliographic_title":"Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment"}]}]},"item_8_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Time spectra of 73-keV X-rays were successfully observed with a scintillation detector using a Bi2O3-nanoparticle-doped plastic scintillator (PLS) and silicon avalanche photodiode (Si-APD). A 5 wt% Bi2O3-nanoparticle-doped PLS was fabricated and cut out to be mm and 0.9 mm thick, and it was mounted on a Si-APD operating in proportional mode. An organic scintillator of [2-(4-tert-butylphenyl)-5-(4-phenylphenyl)]-1,3,4-oxadiazole was used for the PLS by 1.68 mol% of polystyrene solvent. When the PLS and Si-APD were cooled to 30° C, a good time resolution of 0.35 ns (full width at half maximum) was obtained for 73.04-keV X-rays when measuring a time structure of the multibunch mode in synchrotron ring operation. The Si-APD scintillation detector mounting a Bi2O3-nanoparticle-doped PLS can be applied well to research fields that need both a high detection efficiency and a subnanosecond time resolution with a photon energy of more than 70 keV, such as synchrotron radiation nuclear resonant scattering on 193Ir.","subitem_description_type":"Abstract"}]},"item_8_relation_14":{"attribute_name":"DOI","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"10.1016/j.nima.2020.163908","subitem_relation_type_select":"DOI"}}]},"item_8_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_type_id":{"subitem_relation_type_id_text":"https://www.sciencedirect.com/science/article/pii/S0168900220303995","subitem_relation_type_select":"URI"}}]},"item_8_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0168-9002","subitem_source_identifier_type":"ISSN"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Kishimoto, Shunji"}],"nameIdentifiers":[{"nameIdentifier":"882918","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koshimizu, Masanori"}],"nameIdentifiers":[{"nameIdentifier":"882919","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Hiyama, Fumiyuki"}],"nameIdentifiers":[{"nameIdentifier":"882920","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Haruki, Rie"}],"nameIdentifiers":[{"nameIdentifier":"882921","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishikido, Fumihiko"}],"nameIdentifiers":[{"nameIdentifier":"882922","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Koshimizu, Masanori","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"882923","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Nishikido, Fumihiko","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"882924","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Measurements of 73-keV X-ray time spectrum with avalanche-photodiode scintillation detector using Bi2O3-nanoparticle-doped plastic scintillator","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Measurements of 73-keV X-ray time spectrum with avalanche-photodiode scintillation detector using Bi2O3-nanoparticle-doped plastic scintillator"}]},"item_type_id":"8","owner":"1","path":["1"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-08-04"},"publish_date":"2020-08-04","publish_status":"0","recid":"80281","relation_version_is_last":true,"title":["Measurements of 73-keV X-ray time spectrum with avalanche-photodiode scintillation detector using Bi2O3-nanoparticle-doped plastic scintillator"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T21:38:33.400686+00:00"}