WEKO3
アイテム
[11C]phosgene: Synthesis and application for development of PET radiotracers
https://repo.qst.go.jp/records/80191
https://repo.qst.go.jp/records/80191b56f928e-0119-4448-a78c-f7dc0536cd74
| Item type | 学術雑誌論文 / Journal Article(1) | |||||
|---|---|---|---|---|---|---|
| 公開日 | 2020-06-26 | |||||
| タイトル | ||||||
| タイトル | [11C]phosgene: Synthesis and application for development of PET radiotracers | |||||
| 言語 | ||||||
| 言語 | eng | |||||
| 資源タイプ | ||||||
| 資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
| 資源タイプ | journal article | |||||
| アクセス権 | ||||||
| アクセス権 | metadata only access | |||||
| アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
| 著者 |
Fukumura, Toshimitsu
× Fukumura, Toshimitsu× Mori, Wakana× Ogawa, Masanao× Fujinaga, Masayuki× Ming-Rong, Zhang× Toshimitsu, Fukumura× Wakana, Mori× Masanao, Ogawa× Masayuki, Fujinaga× Zhang, Ming-Rong |
|||||
| 抄録 | ||||||
| 内容記述タイプ | Abstract | |||||
| 内容記述 | Carbon-11-labeled phosgene ([11C]phosgene, [11C]COCl2) is a useful labeling agent that connects two heteroatoms by inserting [11C]carbonyl (11C=O) function in carbamates, ureas, and carbonates, which are components of biologically important heterocyclic compounds and functional groups in drugs as a linker of fragments with in vivo stability. Development of 11C-labeled PET tracers has been performed using [11C]phosgene as a labeling agent. However, [11C]phosgene has not been frequently used for 11C-labeling because preparation of [11C]phosgene required dedicated synthesis apparatus (not commercially available) and had problems in reproducibility and reliability. In our laboratory, an improved method for synthesizing [11C]phosgene using a carbon tetrachloride detection tube kit in environmental air analysis and the automated synthesis system for preparing [11C]phosgene have been developed in 2009. This apparatus has been used for routine synthesis of 11C-labeled tracers 1–4 times/week. Using [11C]phosgene we have developed and produced many PET radiotracers containing [11C]urea and [11C]carbamate moieties. In this review, we report the performance of our method for preparing [11C]phosgene, including automated synthesis apparatus developed in house, and the application of [11C]phosgene for development and production of 11C-labeled PET tracers. | |||||
| 書誌情報 |
Nuclear Medicine and Biology 巻 92, p. 138-148, 発行日 2021-01 |
|||||
| 出版者 | ||||||
| 出版者 | Elsevier | |||||
| ISSN | ||||||
| 収録物識別子タイプ | ISSN | |||||
| 収録物識別子 | 0969-8051 | |||||
| DOI | ||||||
| 識別子タイプ | DOI | |||||
| 関連識別子 | 10.1016/j.nucmedbio.2020.04.007 | |||||
| 関連サイト | ||||||
| 識別子タイプ | URI | |||||
| 関連識別子 | https://www.sciencedirect.com/science/article/pii/S0969805120301190 | |||||