WEKO3
アイテム
Internal and interfacial structure analysis of graft-type fluorinated polymer electrolyte membrane by smallangle X-ray scattering in the high-q range
https://repo.qst.go.jp/records/80037
https://repo.qst.go.jp/records/800374d198db6-0d2b-4902-9ec9-710b85f0a784
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2020-01-23 | |||||
タイトル | ||||||
タイトル | Internal and interfacial structure analysis of graft-type fluorinated polymer electrolyte membrane by smallangle X-ray scattering in the high-q range | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Duy Tap, Tran
× Duy Tap, Tran× Ly Nguyen, La× Hasegawa, Shin× Sawada, Shinichi× Quang Luan, Le× Maekawa, Yasunari× Hasegawa, Shin× Sawada, Shinichi× Maekawa, Yasunari |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The hierarchical structures of poly(styrenesulfonic acid)-grafted poly(ethylene-co-tetrafluoroethylene) polymer electrolyte membrane (ETFE-PEM) with different scale ranges including lamellar spacing, interfacial thickness, and intra-structure of conducting layers consisting of graft-polymers and water were evaluated by SAXS in terms of background scattering (IB(q)). First, IB(q) was roughly estimated by modifying Ruland’s method and then optimized to avoid overestimation using a “contribution factor”, which is defined as the contribution of IB(q) to the observed scattering intensities over the entire q range. Then, IB(q) was optimized again by using Ruland’s equation to select proper q-range for interfacial thickness evaluation. The lamellar spacing, which is observed in the low-q range, was not altered by background correction. In contrast, in the high-q range, the interfacial thickness and the internal structures of the conducting layers can be estimated only after correction for the background scattering data. These results clearly show that the hierarchical structures of graft-type PEMs were strongly affected by the background correction in the high-q range. Moreover, the proposed procedure for IB(q) is crucial for the determination of accurate interfacial thickness but not intrastructure of conducting layers. Note that the modified Ruland’s method can be used as an altermative method for determination of background intensity. | |||||
書誌情報 |
Journal of Applied Polymer Science 巻 137, 号 35, 発行日 2020-01 |
|||||
出版者 | ||||||
出版者 | Wiley | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0021-8995 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1002/app.49029 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://onlinelibrary.wiley.com/doi/abs/10.1002/app.49029 |