{"_buckets": {"deposit": "45712eb7-90df-4c87-ad88-11951f1406de"}, "_deposit": {"created_by": 1, "id": "77875", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "77875"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00077875", "sets": ["29"]}, "author_link": ["813900", "813910", "813911", "813907", "813904", "813901", "813912", "813898", "813906", "813897", "813903", "813909", "813908", "813905", "813902", "813913", "813914", "813899"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-12-07", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "Microdosimetry with the microdosimetric kinetic (MK) model is a method to estimate the biological effects of the radiations which measures the dose absorbed by a micrometer-sized volume, namely a specific energy. The MK model developed by National Institute of Radiological Sciences (NIRS) is currently the world\u0027s standard biological model for calculating biological effects, which is known to be very good for carbon ions. NIRS recently announced a multi-ion treatment plan to produce better tumor outcomes from increasing the LET in tumors. This plan will use helium, carbon, oxygen and neon ions to treat pancreatic cancer. To estimate biological effect in multi-ion therapy, we measured lineal energy spectra of each ion by using the silicon- on-insulator (SOI) microdosimeter with well-defined 3D-sensitive volumes (SV) developed by the Centre for Medical Radiation Physics (CMRP) at the University of Wollongong. The 166, 313, 374, 430 MeV/u of each pristine helium, carbon, oxygen and neon ions were irradiated to the SOI microdosimeter of different depth in PMMA to obtain the microdosimetric spectra. The parameters of the MK model were then obtained by optimizing the result with the survival curves obtained by irradiating the human pancreatic carcinoma (Mia PaCa-2) with each of four ions and fitting them to the LQ model.", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "The 1st Annual Conference of the Particle Therapy Co-operative Group Asia-Oceania (PTCOG-AO'19)", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "Sung Hyun, Lee"}], "nameIdentifiers": [{"nameIdentifier": "813897", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizushima, Kota"}], "nameIdentifiers": [{"nameIdentifier": "813898", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakata, Dousatsu"}], "nameIdentifiers": [{"nameIdentifier": "813899", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakama, Makoto"}], "nameIdentifiers": [{"nameIdentifier": "813900", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kohno, Ryosuke"}], "nameIdentifiers": [{"nameIdentifier": "813901", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwata, Yoshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "813902", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki"}], "nameIdentifiers": [{"nameIdentifier": "813903", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Masao"}], "nameIdentifiers": [{"nameIdentifier": "813904", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku"}], "nameIdentifiers": [{"nameIdentifier": "813905", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sung-Hyun, Lee", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813906", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Mizushima, Kota", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813907", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakata, Dousatsu", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813908", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Sakama, Makoto", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813909", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Kohno, Ryosuke", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813910", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Iwata, Yoshiyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813911", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Shirai, Toshiyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813912", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Suzuki, Masao", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813913", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Inaniwa, Taku", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "813914", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "eng"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "Microdosimetric study at the NIRS scanning beam for the multi-ion therapy", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "Microdosimetric study at the NIRS scanning beam for the multi-ion therapy"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/77875", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-12-09"}, "publish_date": "2019-12-09", "publish_status": "0", "recid": "77875", "relation": {}, "relation_version_is_last": true, "title": ["Microdosimetric study at the NIRS scanning beam for the multi-ion therapy"], "weko_shared_id": -1}
  1. 学会発表・講演等
  2. 口頭発表

Microdosimetric study at the NIRS scanning beam for the multi-ion therapy

https://repo.qst.go.jp/records/77875
https://repo.qst.go.jp/records/77875
9d6a9e0c-b94b-442c-92f4-1c4e33fc6665
Item type 会議発表用資料 / Presentation(1)
公開日 2019-12-09
タイトル
タイトル Microdosimetric study at the NIRS scanning beam for the multi-ion therapy
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Sung Hyun, Lee

× Sung Hyun, Lee

WEKO 813897

Sung Hyun, Lee

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 813898

Mizushima, Kota

Search repository
Sakata, Dousatsu

× Sakata, Dousatsu

WEKO 813899

Sakata, Dousatsu

Search repository
Sakama, Makoto

× Sakama, Makoto

WEKO 813900

Sakama, Makoto

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 813901

Kohno, Ryosuke

Search repository
Iwata, Yoshiyuki

× Iwata, Yoshiyuki

WEKO 813902

Iwata, Yoshiyuki

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 813903

Shirai, Toshiyuki

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 813904

Suzuki, Masao

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 813905

Inaniwa, Taku

Search repository
Sung-Hyun, Lee

× Sung-Hyun, Lee

WEKO 813906

en Sung-Hyun, Lee

Search repository
Mizushima, Kota

× Mizushima, Kota

WEKO 813907

en Mizushima, Kota

Search repository
Sakata, Dousatsu

× Sakata, Dousatsu

WEKO 813908

en Sakata, Dousatsu

Search repository
Sakama, Makoto

× Sakama, Makoto

WEKO 813909

en Sakama, Makoto

Search repository
Kohno, Ryosuke

× Kohno, Ryosuke

WEKO 813910

en Kohno, Ryosuke

Search repository
Iwata, Yoshiyuki

× Iwata, Yoshiyuki

WEKO 813911

en Iwata, Yoshiyuki

Search repository
Shirai, Toshiyuki

× Shirai, Toshiyuki

WEKO 813912

en Shirai, Toshiyuki

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 813913

en Suzuki, Masao

Search repository
Inaniwa, Taku

× Inaniwa, Taku

WEKO 813914

en Inaniwa, Taku

Search repository
抄録
内容記述タイプ Abstract
内容記述 Microdosimetry with the microdosimetric kinetic (MK) model is a method to estimate the biological effects of the radiations which measures the dose absorbed by a micrometer-sized volume, namely a specific energy. The MK model developed by National Institute of Radiological Sciences (NIRS) is currently the world's standard biological model for calculating biological effects, which is known to be very good for carbon ions. NIRS recently announced a multi-ion treatment plan to produce better tumor outcomes from increasing the LET in tumors. This plan will use helium, carbon, oxygen and neon ions to treat pancreatic cancer. To estimate biological effect in multi-ion therapy, we measured lineal energy spectra of each ion by using the silicon- on-insulator (SOI) microdosimeter with well-defined 3D-sensitive volumes (SV) developed by the Centre for Medical Radiation Physics (CMRP) at the University of Wollongong. The 166, 313, 374, 430 MeV/u of each pristine helium, carbon, oxygen and neon ions were irradiated to the SOI microdosimeter of different depth in PMMA to obtain the microdosimetric spectra. The parameters of the MK model were then obtained by optimizing the result with the survival curves obtained by irradiating the human pancreatic carcinoma (Mia PaCa-2) with each of four ions and fitting them to the LQ model.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 The 1st Annual Conference of the Particle Therapy Co-operative Group Asia-Oceania (PTCOG-AO'19)
発表年月日
日付 2019-12-07
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:33:05.881283
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3