Ion-production efficiency of a singly charged ion source developed toward a 11C irradiation facility for cancer therapy
https://repo.qst.go.jp/records/77565
https://repo.qst.go.jp/records/775657a6d96ba-7ec9-4207-bb61-c95ccc0a3db1
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-21 | |||||
タイトル | ||||||
タイトル | Ion-production efficiency of a singly charged ion source developed toward a 11C irradiation facility for cancer therapy | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Katagiri, Ken
× Katagiri, Ken× Wakui, Takashi× Hojo, Satoru× A Yu, Boytsov,× D. Donets, E.× E. Donets, E.× Yu. Ramzdorf, A.× Noda, Akira× Shirai, Toshiyuki× Noda, Koji× Ken, Katagiri× Takashi, Wakui× Satoru, Hojo× Akira, Noda× Toshiyuki, Shirai× Koji, Noda |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The ion-production efficiency of a newly developed singly charged ion source (SCIS) has been investigated to discuss the possibility of it being used in an isotope separation on-line system that provides 11C ions for heavy-ion cancer therapy with simultaneous verification of the irradiation field using positron emission tomography. The SCIS uses a low-energy hollow electron beam to produce singly charged carbon ions efficiently. To deliver sufficient 11C ions to the treatment room from a limited amount of 11C molecules, which are produced from a boron compound target and proton-beam irradiation via the 11B(p,n)11C reaction, the SCIS must have high ion-production efficiency. To realize this high efficiency, the SCIS was designed using a three-dimensional particle-in-cell code in previous work. With the fabricated SCIS, we performed experiments to measure the efficiency of producing CO+2 ions from nonradioactive 12CO2 molecules and C+ ions from nonradioactive 12CH4 molecules. We found that the SCIS achieved efficiencies of εC+=4×10−3 (0.4%) for C+ production and εCO+2=0.107 (10.7%) for CO+2 production. | |||||
書誌情報 |
Review of Scientific Instruments 巻 90, 号 5, p. 053303, 発行日 2019-05 |
|||||
出版者 | ||||||
出版者 | AIP | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 0034-6748 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1063/1.5090167 | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://aip.scitation.org/doi/10.1063/1.5090167 |