WEKO3
アイテム
{"_buckets": {"deposit": "72806f30-f4b8-4417-ad7b-f7b0017bff54"}, "_deposit": {"created_by": 1, "id": "77442", "owners": [1], "pid": {"revision_id": 0, "type": "depid", "value": "77442"}, "status": "published"}, "_oai": {"id": "oai:repo.qst.go.jp:00077442", "sets": ["29"]}, "author_link": ["802213", "802208", "802217", "802211", "802222", "802212", "802216", "802220", "802221", "802224", "802210", "802223", "802209", "802214", "802207", "802225", "802226", "802215", "802218", "802219"], "item_10005_date_7": {"attribute_name": "発表年月日", "attribute_value_mlt": [{"subitem_date_issued_datetime": "2019-11-02", "subitem_date_issued_type": "Issued"}]}, "item_10005_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "The alpha-emitting radiopharmaceutical meta-[211At]astatobenzylguanidine (211At-MABG) has potential as a metastatic pheochromocytoma treatment. As 211At-MABG does not emit gamma-rays suitable for dosimetry and imaging, 211At-MABG needs a companion diagnostic imaging agent such as meta-[123I]iodobenzylguanidine (123I-MIBG) to be used in making treatment decisions. We evaluated the similarities and differences between 123I-MIBG and 211At-MABG in biodistribution in normal mice. BALB/c mice were injected with 123I-MIBG or 211At-MABG, and the radioactivity levels (%ID/g) in the tissues were determined at 1 and 30 min, and 1, 3, 6, and 24 h after the injection.\nResults: 211At-MABG and 123I-MIBG showed very similar biodistribution profiles in normal mice at every time point. \nConclusions: 123I-MIBG can be used for dosimetry and imaging for decisions regarding treatment with 211At-MABG radiotherapy.\n", "subitem_description_type": "Abstract"}]}, "item_10005_description_6": {"attribute_name": "会議概要(会議名, 開催地, 会期, 主催者等)", "attribute_value_mlt": [{"subitem_description": "第59回日本核医学会学術総会", "subitem_description_type": "Other"}]}, "item_access_right": {"attribute_name": "アクセス権", "attribute_value_mlt": [{"subitem_access_right": "metadata only access", "subitem_access_right_uri": "http://purl.org/coar/access_right/c_14cb"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "趙, 松吉"}], "nameIdentifiers": [{"nameIdentifier": "802207", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "吉永, 恵一郎"}], "nameIdentifiers": [{"nameIdentifier": "802208", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "粟生木, 美穂"}], "nameIdentifiers": [{"nameIdentifier": "802209", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "右近, 直之"}], "nameIdentifiers": [{"nameIdentifier": "802210", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "下山, 彩希"}], "nameIdentifiers": [{"nameIdentifier": "802211", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "西嶋, 剣一"}], "nameIdentifiers": [{"nameIdentifier": "802212", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鷲山, 幸信"}], "nameIdentifiers": [{"nameIdentifier": "802213", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "鷲野, 弘明"}], "nameIdentifiers": [{"nameIdentifier": "802214", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "高橋, 和弘"}], "nameIdentifiers": [{"nameIdentifier": "802215", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "東, 達也"}], "nameIdentifiers": [{"nameIdentifier": "802216", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "伊藤, 浩"}], "nameIdentifiers": [{"nameIdentifier": "802217", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Zhao, Songji", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802218", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Yoshinaga, Keiichiro", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802219", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Aoki, Miho", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802220", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ukon, Naoyuki", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802221", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Nishijima, Kenichi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802222", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Koushin, Washiyama", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802223", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Washino, Komei", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802224", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Higashi, Tatsuya", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802225", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "Ito, Hiroshi", "creatorNameLang": "en"}], "nameIdentifiers": [{"nameIdentifier": "802226", "nameIdentifierScheme": "WEKO"}]}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "conference object", "resourceuri": "http://purl.org/coar/resource_type/c_c94f"}]}, "item_title": "正常マウスにおける123I-MIBGと211At-MABGの体内動態の評価", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "正常マウスにおける123I-MIBGと211At-MABGの体内動態の評価"}]}, "item_type_id": "10005", "owner": "1", "path": ["29"], "permalink_uri": "https://repo.qst.go.jp/records/77442", "pubdate": {"attribute_name": "公開日", "attribute_value": "2019-11-15"}, "publish_date": "2019-11-15", "publish_status": "0", "recid": "77442", "relation": {}, "relation_version_is_last": true, "title": ["正常マウスにおける123I-MIBGと211At-MABGの体内動態の評価"], "weko_shared_id": -1}
正常マウスにおける123I-MIBGと211At-MABGの体内動態の評価
https://repo.qst.go.jp/records/77442
https://repo.qst.go.jp/records/77442111b2e4e-cd1a-4c5d-b43a-d8fe3e6121fd
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-11-15 | |||||
タイトル | ||||||
タイトル | 正常マウスにおける123I-MIBGと211At-MABGの体内動態の評価 | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
趙, 松吉
× 趙, 松吉× 吉永, 恵一郎× 粟生木, 美穂× 右近, 直之× 下山, 彩希× 西嶋, 剣一× 鷲山, 幸信× 鷲野, 弘明× 高橋, 和弘× 東, 達也× 伊藤, 浩× Zhao, Songji× Yoshinaga, Keiichiro× Aoki, Miho× Ukon, Naoyuki× Nishijima, Kenichi× Koushin, Washiyama× Washino, Komei× Higashi, Tatsuya× Ito, Hiroshi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | The alpha-emitting radiopharmaceutical meta-[211At]astatobenzylguanidine (211At-MABG) has potential as a metastatic pheochromocytoma treatment. As 211At-MABG does not emit gamma-rays suitable for dosimetry and imaging, 211At-MABG needs a companion diagnostic imaging agent such as meta-[123I]iodobenzylguanidine (123I-MIBG) to be used in making treatment decisions. We evaluated the similarities and differences between 123I-MIBG and 211At-MABG in biodistribution in normal mice. BALB/c mice were injected with 123I-MIBG or 211At-MABG, and the radioactivity levels (%ID/g) in the tissues were determined at 1 and 30 min, and 1, 3, 6, and 24 h after the injection. Results: 211At-MABG and 123I-MIBG showed very similar biodistribution profiles in normal mice at every time point. Conclusions: 123I-MIBG can be used for dosimetry and imaging for decisions regarding treatment with 211At-MABG radiotherapy. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第59回日本核医学会学術総会 | |||||
発表年月日 | ||||||
日付 | 2019-11-02 | |||||
日付タイプ | Issued |