Localized dose dependence of DNA double strand break region in human cells irradiated by SPICE microbeam

https://repo.qst.go.jp/records/76824
https://repo.qst.go.jp/records/76824
bbfb66e6-ff05-425f-a0f4-6c5f608877bd
Item type 会議発表用資料 / Presentation(1)
公開日 2019-09-17
タイトル
タイトル Localized dose dependence of DNA double strand break region in human cells irradiated by SPICE microbeam
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Ohsawa, Daisuke

× Ohsawa, Daisuke

WEKO 822795

Ohsawa, Daisuke

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 822796

Konishi, Teruaki

Search repository
Ohsawa, Daisuke

× Ohsawa, Daisuke

WEKO 822797

en Ohsawa, Daisuke

Search repository
Konishi, Teruaki

× Konishi, Teruaki

WEKO 822798

en Konishi, Teruaki

Search repository
抄録
内容記述タイプ Abstract
内容記述 Single Particle Irradiation system to Cell, SPICE, at the National Institute of Radiological Sciences(NIRS) is an advanced outstanding cell irradiation system capable of a single-proton single-cell irradiation with high throughput and without losing accuracy. It delivers a focused vertical microbeam of 3.4 MeV protons to a targeted cell nucleus or cytoplasm. Such advantages of the SPCIE have motivated further investigations on the cellular response to different DNA damage complexities induced by ionizing radiation. Previously, we reported an accurate and systematic investigation of the SPICE microbeam profile using a FNTD [2]. In the present study, as a second step, we discuss the localized dose distribution in a targeted nucleus of human lung normal WI-38 cells and its correlation with intensity and area of DNA double strand break (DSB) region, visualized by immunostaining against g-H2AX. Finally, superlinear dependence of the g-H2AX spot area to the beam area was interestingly observed for large number of protons per position, suggesting that the penumbra dose fraction in the localized dose distribution significantly contributed to the DSB induction.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 19th International Conference on Solid State Dosimetry (SSD19)
発表年月日
日付 2019-09-19
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:29:22.756782
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3