ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Experimental Investigation of the Cs Behavior in the Cesiated H- Ion Source during High Power Long Beam Pulse

https://repo.qst.go.jp/records/76711
https://repo.qst.go.jp/records/76711
59e2ca36-b1f1-466a-a4f0-9a3b97c17ac3
Item type 会議発表用資料 / Presentation(1)
公開日 2019-09-10
タイトル
タイトル Experimental Investigation of the Cs Behavior in the Cesiated H- Ion Source during High Power Long Beam Pulse
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 mae quinones Saquilayan, Glynnis

× mae quinones Saquilayan, Glynnis

WEKO 782199

mae quinones Saquilayan, Glynnis

Search repository
Kashiwagi, Mieko

× Kashiwagi, Mieko

WEKO 782200

Kashiwagi, Mieko

Search repository
Tobari, Hiroyuki

× Tobari, Hiroyuki

WEKO 782201

Tobari, Hiroyuki

Search repository
Hiratsuka, Junichi

× Hiratsuka, Junichi

WEKO 782202

Hiratsuka, Junichi

Search repository
Ichikawa, Masahiro

× Ichikawa, Masahiro

WEKO 782203

Ichikawa, Masahiro

Search repository
Umeda, Naotaka

× Umeda, Naotaka

WEKO 782204

Umeda, Naotaka

Search repository
Watanabe, Kazuhiro

× Watanabe, Kazuhiro

WEKO 782205

Watanabe, Kazuhiro

Search repository
Kojima, Atsushi

× Kojima, Atsushi

WEKO 782206

Kojima, Atsushi

Search repository
mae quinones Saquilayan, Glynnis

× mae quinones Saquilayan, Glynnis

WEKO 782207

en mae quinones Saquilayan, Glynnis

Search repository
Kashiwagi, Mieko

× Kashiwagi, Mieko

WEKO 782208

en Kashiwagi, Mieko

Search repository
Tobari, Hiroyuki

× Tobari, Hiroyuki

WEKO 782209

en Tobari, Hiroyuki

Search repository
Hiratsuka, Junichi

× Hiratsuka, Junichi

WEKO 782210

en Hiratsuka, Junichi

Search repository
Ichikawa, Masahiro

× Ichikawa, Masahiro

WEKO 782211

en Ichikawa, Masahiro

Search repository
Umeda, Naotaka

× Umeda, Naotaka

WEKO 782212

en Umeda, Naotaka

Search repository
Watanabe, Kazuhiro

× Watanabe, Kazuhiro

WEKO 782213

en Watanabe, Kazuhiro

Search repository
Kojima, Atsushi

× Kojima, Atsushi

WEKO 782214

en Kojima, Atsushi

Search repository
抄録
内容記述タイプ Abstract
内容記述 Long pulse operation of H- negative ion beams having energies of 0.5 MeV with the current density of 150 A/m2 for 100 s were demonstrated in the MeV facility in QST for the development of neutral beam injector (NBI) systems of fusion reactors. The main challenge for the long pulse operation is to suppress beam current degradation which is caused by complications arising from the use of cesium to enhance the H- production in the ion source. In the test, optical emission spectroscopy of the Cs line emissions were analyzed to understand the behavior of Cs during the long pulse arc discharge. The effect of temperature control in the chamber walls influences the Cs coverage in the ion source and results in stable beam operation as the amount of Cs neutrals in the plasma is properly controlled.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 18th International Conference on Ion Sources
発表年月日
日付 2019-09-03
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:45:27.529245
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3