ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 原著論文

The radiobiological effects of He, C and Ne ions as a function of LET on various glioblastoma cell lines

https://repo.qst.go.jp/records/76668
https://repo.qst.go.jp/records/76668
c1af4766-34a7-42da-9577-678fba730caa
Item type 学術雑誌論文 / Journal Article(1)
公開日 2019-09-05
タイトル
タイトル The radiobiological effects of He, C and Ne ions as a function of LET on various glioblastoma cell lines
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ journal article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Tsuey Chew, Ming

× Tsuey Chew, Ming

WEKO 848321

Tsuey Chew, Ming

Search repository
David A., Bradley

× David A., Bradley

WEKO 848322

David A., Bradley

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 848323

Suzuki, Masao

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 848324

Matsufuji, Naruhiro

Search repository
Murakami, Takeshi

× Murakami, Takeshi

WEKO 848325

Murakami, Takeshi

Search repository
Bleddyn, Jones

× Bleddyn, Jones

WEKO 848326

Bleddyn, Jones

Search repository
Andrew, Nisbet

× Andrew, Nisbet

WEKO 848327

Andrew, Nisbet

Search repository
Tsuey Chew, Ming

× Tsuey Chew, Ming

WEKO 848328

en Tsuey Chew, Ming

Search repository
Suzuki, Masao

× Suzuki, Masao

WEKO 848329

en Suzuki, Masao

Search repository
Matsufuji, Naruhiro

× Matsufuji, Naruhiro

WEKO 848330

en Matsufuji, Naruhiro

Search repository
Murakami, Takeshi

× Murakami, Takeshi

WEKO 848331

en Murakami, Takeshi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The effects of the charged ion species 4He, 12C and 20Ne on glioblastoma multiforme (GBM) T98G, U87 and LN18 cell lines were compared with the effects of 200 kVp X-rays (1.7 keV/μm). These cell lines have different genetic profiles. Individual GBM relative biological effectiveness (RBE) was estimated in two ways: the RBE10 at 10% survival fraction and the RBE2 Gy after 2 Gy doses. The linear quadratic model radiosensitivity parameters α and β and the α/β ratio of each ion type were determined as a function of LET. Mono-energetic 4
He, 12C and 20Ne ions were generated by the Heavy Ion Medical Accelerator at the National Institute of Radiological Sciences in Chiba, Japan. Colony-formation
assays were used to evaluate the survival fractions. The LET of the various ions used ranged from 2.3 to 100 keV/μm (covering the depth–dose plateau region to clinically relevant LET at the Bragg peak). For U87 and LN18, the RBE10
increased with LET and peaked at 85 keV/μm, whereas T98G peaked at 100 keV/μm. All three GBM α parameters peaked at 100 keV/μm. There is a statistically significant difference between the three GBM RBE10 values, except at 100 keV/μm (P < 0.01), and a statistically significant difference between the α values of the GBM cell lines, except at 85 and 100 keV/μm. The biological response varied depending on the GBM cell lines and on the ions used.
書誌情報 Journal of Radiation Research

巻 60, 号 2, p. 178-188, 発行日 2019-03
出版者
出版者 Oxford University Press
ISSN
収録物識別子タイプ ISSN
収録物識別子 1349-9157
DOI
識別子タイプ DOI
関連識別子 10.1093/jrr/rry099
関連サイト
識別子タイプ URI
関連識別子 https://academic.oup.com/jrr/article/60/2/178/5280421
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 18:17:41.645090
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3