WEKO3
アイテム
Carbon-ion radiotherapy for lymph node oligo-recurrence: a multi-institutional study by the Japan Carbon-Ion Radiation Oncology Study Group (J-CROS).
https://repo.qst.go.jp/records/75865
https://repo.qst.go.jp/records/758657cc572c6-f54b-4604-a9a8-cb7b7e9e5345
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-05-21 | |||||
タイトル | ||||||
タイトル | Carbon-ion radiotherapy for lymph node oligo-recurrence: a multi-institutional study by the Japan Carbon-Ion Radiation Oncology Study Group (J-CROS). | |||||
言語 | ||||||
言語 | eng | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
Okonogi, Noriyuki
× Okonogi, Noriyuki× Kaminuma, Takuya× Okimoto, Tomoaki× Shinoto, Makoto× Yamamoto, Naoyoshi× Yamada, Shigeru× Murata, Kazutoshi× Ohno, Tatsuya× Shioyama, Yoshiyuki× Tsuji, Hiroshi× Nakano, Takashi× Kamada, Tadashi× Okonogi, Noriyuki× Kaminuma, Takuya× Okimoto, Tomoaki× Shinoto, Makoto× Yamamoto, Naoyoshi× Yamada, Shigeru× Murata, Kazutoshi× Ohno, Tatsuya× Shioyama, Yoshiyuki× Tsuji, Hiroshi× Nakano, Takashi× Kamada, Tadashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | Background: The efficacy of carbon-ion radiotherapy (C-ion RT) for lymph node (LN) oligo-recurrence has only been evaluated in limited single-center studies. We aimed to investigate the benefit of C-ion RT for LN oligo-recurrence in a large multi-center study. Methods: Patients who received C-ion RT between December 1996 and December 2015 at 4 participating facilities and who met the following eligibility criteria were included: (i) histological or clinical diagnosis of LN recurrence; (ii) controlled primary lesion; (iii) no recurrence other than LN; (iv) LN recurrence involved in a single lymphatic site; and (v) age ≥ 20 years. Results: A total of 323 patients were enrolled. Median follow-up period was 34 months for surviving patients. The most common dose fractionation of C-ion RT was 48.0 Gy (relative biological effectiveness) in 12 fractions. Forty-seven patients had a history of RT at the recurrent site. The 2-year local control (LC) and overall survival (OS) rates after C-ion RT were 85% and 63%, respectively. Only 1 patient developed grade-3 toxicity. Factors such as LN diameter, histology, and history of previous RT did not correlate with LC. Smaller diameters (< 30 mm) and numbers (≤ 3) of LN metastases as well as longer disease-free intervals post-primary therapy (≥ 16 months) were associated with significantly better OS. Conclusions: C-ion RT for LN oligo-recurrence appeared to be effective and safe. C-ion RT may provide a survival benefit to patients with LN oligo-recurrence, particularly to those with few LN metastases, smaller LN diameters, and longer disease-free intervals. |
|||||
書誌情報 |
International journal of clinical oncology 巻 24, 号 9, p. 1143-1150, 発行日 2019-01 |
|||||
出版者 | ||||||
出版者 | Springer-Verlag Tokyo | |||||
ISSN | ||||||
収録物識別子タイプ | ISSN | |||||
収録物識別子 | 1341-9625 | |||||
PubMed番号 | ||||||
識別子タイプ | PMID | |||||
関連識別子 | 30968270 | |||||
DOI | ||||||
識別子タイプ | DOI | |||||
関連識別子 | 10.1007/s10147-019-01440-y | |||||
関連サイト | ||||||
識別子タイプ | URI | |||||
関連識別子 | https://link.springer.com/article/10.1007%2Fs10147-019-01440-y |