WEKO3
-
RootNode
アイテム
Assessment of SPECT-CT fusion images and semi-quantitative evaluation of I-123 IMP SPECT in patients with ocular choroidal melanoma.
https://repo.qst.go.jp/records/75679
https://repo.qst.go.jp/records/7567900ff2d40-7719-49fe-93f4-4fafbbd84d43
Item type | 会議発表用資料 / Presentation(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2019-04-23 | |||||
タイトル | ||||||
タイトル | Assessment of SPECT-CT fusion images and semi-quantitative evaluation of I-123 IMP SPECT in patients with ocular choroidal melanoma. | |||||
言語 | ||||||
言語 | jpn | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_c94f | |||||
資源タイプ | conference object | |||||
アクセス権 | ||||||
アクセス権 | metadata only access | |||||
アクセス権URI | http://purl.org/coar/access_right/c_14cb | |||||
著者 |
山崎, 香奈
× 山崎, 香奈× 西井, 龍一× 東, 達也× 牧島, 弘和× 粕谷, 吾朗× 辻, 比呂志× 吉永, 恵一郎× 鎌田, 正× Yamazaki, Kana× Nishii, Ryuichi× Higashi, Tatsuya× Makishima, Hirokazu× Kasuya, Goro× Tsuji, Hiroshi× Yoshinaga, Keiichiro× Kamada, Tadashi |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | [Objective] Choroidal melanoma is the most common primary ocular malignant tumor. I-123 IMP SPECT imaging was reported to be useful diagnostic imaging tool, however the diagnostic values in terms of assessment of fused image with CT/MRI and the semi-quantitative evaluation of the IMP-SPECT are still left to be discussed. [Materials and Methods] Among patients who visited our institution for carbon-ion radiotherapy, ten patients who received I-123 IMP SPECT imaging were enrolled in this investigation. Fifteen min and 24 hours after intravenous injection of the radiotracer, SPECT imaging was performed using a gamma camera (E.CAM, Canon Medical, Tokyo, Japan). All acquired SPECT images were fused with CT or MRI images using a fusion viewer software (AZE-Hayabusa, AZE, Japan). ROIs of the tumor, contralateral normal choroidal tissue and normal soft tissue referring to CT or MRI image were analyzed, followed by semi-quantitative evaluation was assessed using non-parametric Wilcoxon rank sum test. [Results] All tumors were visualized clearly in the 24h-SPECT image than those in 15min-SPECT image. The uptake index (UI) of the tumor: (tumor count) / (normal soft tissue count) and the contralateral normal choroidal tissue: (normal choroidal tissue count) / (normal soft tissue count) were 3.16+/-0.97 and 1.35+/-0.17, respectively (p < 0.001). The tumor-to-normal tissue ratios was 7.78+/-5.10. [Conclusion] I-123 IMP SPECT imaging performed 24h after injection of the radiotracer and fusion-image-analysis with CT or MRI were useful for detection of the choroidal melanoma. Also semi-quantitative evaluation using the fused images using tumor-UI and T/N ratio were considered to be valuable imaging techniques for diagnosis of the choroidal melanoma. |
|||||
会議概要(会議名, 開催地, 会期, 主催者等) | ||||||
内容記述タイプ | Other | |||||
内容記述 | 第78回日本医学放射線学会総会 | |||||
発表年月日 | ||||||
日付 | 2019-04-14 | |||||
日付タイプ | Issued |
Share
Cite as
山崎, 香奈, 西井, 龍一, 東, 達也, 牧島, 弘和, 粕谷, 吾朗, 辻, 比呂志, 吉永, 恵一郎, 鎌田, 正, Yamazaki, Kana, Nishii, Ryuichi, Higashi, Tatsuya, Makishima, Hirokazu, Kasuya, Goro, Tsuji, Hiroshi, Yoshinaga, Keiichiro, Kamada, Tadashi, 2019, Assessment of SPECT-CT fusion images and semi-quantitative evaluation of I-123 IMP SPECT in patients with ocular choroidal melanoma.
Loading...