ログイン
言語:

WEKO3

  • トップ
  • ランキング
To
lat lon distance
To

Field does not validate



インデックスリンク

インデックスツリー

メールアドレスを入力してください。

WEKO

One fine body…

WEKO

One fine body…

アイテム

  1. 学会発表・講演等
  2. ポスター発表

Assessment of 4DST uptake and Ki-67 index in patients with lung tumor in comparison with FDG uptake.

https://repo.qst.go.jp/records/74787
https://repo.qst.go.jp/records/74787
00545191-ab5e-4e7e-a9cc-ce615ef8be9e
Item type 会議発表用資料 / Presentation(1)
公開日 2019-03-15
タイトル
タイトル Assessment of 4DST uptake and Ki-67 index in patients with lung tumor in comparison with FDG uptake.
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 Nishii, Ryuichi

× Nishii, Ryuichi

WEKO 906783

Nishii, Ryuichi

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 906784

Saga, Tsuneo

Search repository
Sudo, Hitomi

× Sudo, Hitomi

WEKO 906785

Sudo, Hitomi

Search repository
Yoshinaga, Keiichiro

× Yoshinaga, Keiichiro

WEKO 906786

Yoshinaga, Keiichiro

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 906787

Higashi, Tatsuya

Search repository
Nishii, Ryuichi

× Nishii, Ryuichi

WEKO 906788

en Nishii, Ryuichi

Search repository
Saga, Tsuneo

× Saga, Tsuneo

WEKO 906789

en Saga, Tsuneo

Search repository
Sudo, Hitomi

× Sudo, Hitomi

WEKO 906790

en Sudo, Hitomi

Search repository
Yoshinaga, Keiichiro

× Yoshinaga, Keiichiro

WEKO 906791

en Yoshinaga, Keiichiro

Search repository
Higashi, Tatsuya

× Higashi, Tatsuya

WEKO 906792

en Higashi, Tatsuya

Search repository
抄録
内容記述タイプ Abstract
内容記述 Objective: A novel radiopharmaceutical, 4’-[methyl-11C]-thiothymidine (4DST), has been developed as an in vivo cell proliferation marker based on the DNA incorporation method. The purpose of this study was to evaluate 4DST uptake in patients with lung tumor and to correlate the results with proliferative activity and tumor grade, in comparison with 18F-FDG (FDG).
Methods: Investigations of 4DST and FDG PET/CT were performed retrospectively in 23 lesions of 22 patients with lung tumor (18 male and 4 femal, mean age; 67.4+/- 8.6 y.o., median; 69 y.o.). The maximum standardized uptake value (SUVmax) for tumor were calculated. Histopathological diagnosis was proven by surgery when the clinical diagnosis was malignancy. Others were diagnosed as benign lung nodule by clinically follow-up. Proliferative activity as indicated by the Ki-67 index was estimated in tissue specimens.
Results: Of 23 lung tumors examined, 19 lesions were malignant tumor (SqCC; 5, Adenoca.; 14), other 4 lesion were benign after surgery or clinical course observation. In 4DST PET/CT study, SUVmax were 3.04 in malignant lesion (2.89 for SqCC, 3.10 for Adenoca.) and 1.87 in benign lesion, respectively (P<0.05). In FDG PET/CT study, SUVmax were 5.62 in malignant lesion (7.46 for SqCC, 4.96 for Adenoca.) and 4.48 in benign lesion, respectively (n.s.). Linear regression analysis between 4DST and FDG indicated a correlation for SUVmax (R2 = 0.30, P<0.01). The Expression of Ki-67 of SqCC was 32.4 +/- 7.44 and that of Adeno ca. was 24.64 +/- 29.84, respectively (n.s.). Linear regression analysis indicated a correlation between FDG and Ki-67 index of or SUVmax (R2 = 0.50, P<0.005), however a significant correlation between FDG and Ki-67 index was not found in this population of this study. In several case of adenocarcinoma, mixed subtype, were relatively low Ki-67 index while the SUVmax of 4DST were high.
Conclusion: 4DST PET/CT is feasible for imaging of lung tumors, as well as FDG PET/CT.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 世界核医学会(WFNMB2018)
発表年月日
日付 2018-04-21
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 17:55:20.793458
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3