Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector

https://repo.qst.go.jp/records/74759
https://repo.qst.go.jp/records/74759
6f0bc60f-6144-4f98-9f61-7de793ebab91
Item type 一般雑誌記事 / Article(1)
公開日 2019-03-15
タイトル
タイトル Evaluation of Particle Fluence of Cluster and Monomer Ion Beams Using a Solid-state Track Detector
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_6501
資源タイプ article
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 長谷, 純宏

× 長谷, 純宏

WEKO 737519

長谷, 純宏

Search repository
佐藤, 勝也

× 佐藤, 勝也

WEKO 737520

佐藤, 勝也

Search repository
千葉, 敦也

× 千葉, 敦也

WEKO 737521

千葉, 敦也

Search repository
平野, 貴美

× 平野, 貴美

WEKO 737522

平野, 貴美

Search repository
Hase, Yoshihiro

× Hase, Yoshihiro

WEKO 737523

en Hase, Yoshihiro

Search repository
Sato, Katsuya

× Sato, Katsuya

WEKO 737524

en Sato, Katsuya

Search repository
Chiba, Atsuya

× Chiba, Atsuya

WEKO 737525

en Chiba, Atsuya

Search repository
Hirano, Yoshimi

× Hirano, Yoshimi

WEKO 737526

en Hirano, Yoshimi

Search repository
抄録
内容記述タイプ Abstract
内容記述 The cluster ion-specific irradiation effects have been observed in the analysis of ion-material interaction due to their unique feature such as very high-density energy deposition. The cluster ion beams may also cause a unique irradiation effects in biological samples, however, hardly applied so far. This study is aimed to establish an irradiation method of cluster ions for bacteria and investigate the cluster ion-specific effects by comparing the irradiation effects of cluster and monomer ion beams. In order to evaluate the accuracy of the measurement of beam current using a Faraday cup, we measured the particle fluence using a solid-state track detector. The results suggested that the measurement of beam current with the Faraday cup equipped in the TC line is accurate with the possible errors of 3~4% in both cluster and monomer ion beams.
書誌情報 QST Takasaki Annual Report 2017

p. 93, 発行日 2019-03
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:03:07.561759
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3