Accurate measurement of 236U/238U isotope ratio in 10-8 range in Soil using TIMS

https://repo.qst.go.jp/records/72426
https://repo.qst.go.jp/records/72426
4645ef8f-4f2c-4542-86fc-9c892b3b3a4f
Item type 会議発表用資料 / Presentation(1)
公開日 2017-08-31
タイトル
タイトル Accurate measurement of 236U/238U isotope ratio in 10-8 range in Soil using TIMS
言語
言語 eng
資源タイプ
資源タイプ識別子 http://purl.org/coar/resource_type/c_c94f
資源タイプ conference object
アクセス権
アクセス権 metadata only access
アクセス権URI http://purl.org/coar/access_right/c_14cb
著者 S.K.SAHOO

× S.K.SAHOO

WEKO 713363

S.K.SAHOO

Search repository
T.AONO

× T.AONO

WEKO 713364

T.AONO

Search repository
Z.PALACZ

× Z.PALACZ

WEKO 713365

Z.PALACZ

Search repository
P.STEIER

× P.STEIER

WEKO 713366

P.STEIER

Search repository
サフー サラタ クマール

× サフー サラタ クマール

WEKO 713367

en サフー サラタ クマール

Search repository
青野 辰雄

× 青野 辰雄

WEKO 713368

en 青野 辰雄

Search repository
抄録
内容記述タイプ Abstract
内容記述 Precise measurement of uranium isotope ratios with sufficient accuracy is a challenge to resolve the range of natural variation in a representative set of samples. Variations in the isotope ratios 234U/238U, 235U/238U and 236U/238U in natural uranium samples (e.g., uranium ores), are known to exist due to various physical, chemical, mass fractionation, redox transitions, radioactive decay, radioactive disequilibrium, alpha-recoil, and neutron capture.
Uranium was chemically separated from selected Fukushima soil samples with known 137Cs concentration by a two-column separation procedure using UTEVA resin. U isotope ratios were measured using a thermal ionization mass spectrometer (TIMS). The abundance of minor isotopes within the same sample may be so small as to require measurement by specialized detector such as Daly photomultiplier. The TIMS (Phoenix, IsotopX, UK) used has nine Faraday cups collectors and a Daly ion-counting system detector and WARP (wide aperture retardation potential) filter. Abundance sensitivity of 237U using NBS 030a was 5.86 ppb with WARP filter. The limit of detection for 236U/238U measurements using Daly ion counting system with WARP is about 10-9 order. This was evaluated using a certified natural uranium reference material from University of Vienna in house standard (236U/238U = 1.01x10-8). This method represents a significant advance for uranium isotopic composition in analysis of environmental samples. Results will be discussed in detail during presentation.
会議概要(会議名, 開催地, 会期, 主催者等)
内容記述タイプ Other
内容記述 Goldschmidt 2017
発表年月日
日付 2017-08-15
日付タイプ Issued
戻る
0
views
See details
Views

Versions

Ver.1 2023-05-15 19:39:58.144309
Show All versions

Share

Mendeley Twitter Facebook Print Addthis

Cite as

エクスポート

OAI-PMH
  • OAI-PMH JPCOAR 2.0
  • OAI-PMH JPCOAR 1.0
  • OAI-PMH DublinCore
  • OAI-PMH DDI
Other Formats
  • JSON
  • BIBTEX

Confirm


Powered by WEKO3


Powered by WEKO3