{"created":"2023-05-15T14:53:07.103789+00:00","id":72426,"links":{},"metadata":{"_buckets":{"deposit":"0961600d-522e-48ee-ab19-d0622a1f74f4"},"_deposit":{"created_by":1,"id":"72426","owners":[1],"pid":{"revision_id":0,"type":"depid","value":"72426"},"status":"published"},"_oai":{"id":"oai:repo.qst.go.jp:00072426","sets":["10:28"]},"author_link":["713366","713364","713365","713363","713368","713367"],"item_10005_date_7":{"attribute_name":"発表年月日","attribute_value_mlt":[{"subitem_date_issued_datetime":"2017-08-15","subitem_date_issued_type":"Issued"}]},"item_10005_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Precise measurement of uranium isotope ratios with sufficient accuracy is a challenge to resolve the range of natural variation in a representative set of samples. Variations in the isotope ratios 234U/238U, 235U/238U and 236U/238U in natural uranium samples (e.g., uranium ores), are known to exist due to various physical, chemical, mass fractionation, redox transitions, radioactive decay, radioactive disequilibrium, alpha-recoil, and neutron capture. \nUranium was chemically separated from selected Fukushima soil samples with known 137Cs concentration by a two-column separation procedure using UTEVA resin. U isotope ratios were measured using a thermal ionization mass spectrometer (TIMS). The abundance of minor isotopes within the same sample may be so small as to require measurement by specialized detector such as Daly photomultiplier. The TIMS (Phoenix, IsotopX, UK) used has nine Faraday cups collectors and a Daly ion-counting system detector and WARP (wide aperture retardation potential) filter. Abundance sensitivity of 237U using NBS 030a was 5.86 ppb with WARP filter. The limit of detection for 236U/238U measurements using Daly ion counting system with WARP is about 10-9 order. This was evaluated using a certified natural uranium reference material from University of Vienna in house standard (236U/238U = 1.01x10-8). This method represents a significant advance for uranium isotopic composition in analysis of environmental samples. Results will be discussed in detail during presentation.","subitem_description_type":"Abstract"}]},"item_10005_description_6":{"attribute_name":"会議概要(会議名, 開催地, 会期, 主催者等)","attribute_value_mlt":[{"subitem_description":"Goldschmidt 2017","subitem_description_type":"Other"}]},"item_access_right":{"attribute_name":"アクセス権","attribute_value_mlt":[{"subitem_access_right":"metadata only access","subitem_access_right_uri":"http://purl.org/coar/access_right/c_14cb"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"S.K.SAHOO"}],"nameIdentifiers":[{"nameIdentifier":"713363","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"T.AONO"}],"nameIdentifiers":[{"nameIdentifier":"713364","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"Z.PALACZ"}],"nameIdentifiers":[{"nameIdentifier":"713365","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"P.STEIER"}],"nameIdentifiers":[{"nameIdentifier":"713366","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"サフー サラタ クマール","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"青野 辰雄","creatorNameLang":"en"}],"nameIdentifiers":[{"nameIdentifier":"713368","nameIdentifierScheme":"WEKO"}]}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"conference object","resourceuri":"http://purl.org/coar/resource_type/c_c94f"}]},"item_title":"Accurate measurement of 236U/238U isotope ratio in 10-8 range in Soil using TIMS","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Accurate measurement of 236U/238U isotope ratio in 10-8 range in Soil using TIMS"}]},"item_type_id":"10005","owner":"1","path":["28"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-08-31"},"publish_date":"2017-08-31","publish_status":"0","recid":"72426","relation_version_is_last":true,"title":["Accurate measurement of 236U/238U isotope ratio in 10-8 range in Soil using TIMS"],"weko_creator_id":"1","weko_shared_id":-1},"updated":"2023-05-15T19:39:58.041079+00:00"}